If the
CP-Status
parameter is enabled, the processor unit reports asynchronously, i.e. without
any prior request, when a data carrier enters the active field of the read/write head. Depending
on the setting of the parameter
Type and serial number
the
UID
of the data carrier is returned or
the memory contents of the specified auto-read range. This can be specified using the parame-
ters
Auto-Read
Start address
and
Auto-Read Length
.
Enabled/Disabled
Note
The function
CP-Status
is only supported in TCP/IP Multi-Port mode using series
BIS VL, BIS VM and BIS C series read/write heads.
Note
In
Auto-Read
a status message is returned when the parameters
Auto-Read Start
address
and
Auto-Read Length
are used to define a memory range invalid and not
supported by the data carrier being used.
Specifies the start address from which to read in
Auto-Read
mode.
000000…999999
Specifies the number of bytes which are read starting at the given
Auto-Read Start address
in
Auto-Read
mode.
0000…1024
Note
The Auto-Read function is not supported when using BIS-VU read/write heads.
Places the BIS V processor unit in BIS M-41_ _ compatibility mode for using custom read/write
commands together with type BIS M-1_ _- 07 data carriers.
Enabled/Disabled
Note
In
Auto-Read
a status message is returned when the parameters
Auto-Read Start
address
and
Auto-Read Length
are used to define a memory range invalid and not
supported by the data carrier being used.
8.3 RFID Parameter
CP status
Auto-Read Start
address
Auto-Read
Length
Custom
Parameter