BIS V-6107 TCP/IP, USB
Processor Unit
96
9
Protocol
Command ID 'z': Select (Select Data Carrier in Multi-tag Mode)
►
In the Multi-tag Mode, the
Select
command selects a single data carrier from within a data
carrier population. A data carrier that is located in the active read/write zone of the antenna is
accessed and selected directly based on its EPC or its TID and is then available for further
processing.
For the BIS V only ECP or TID can be selected, selecting USER data is not possible. The EPC
and TID are output in reverse order with leading zeros.
Byte
Length
Command element
Value range
00
1
Command ID (ASCII)
'z'
01
1
Head number (ASCII)
'1'…'4'
02
1
Type EPC/TID and USER data (ASCII)
'E': EPC
'T': TID
'U': USER
03
1
1st byte of data carrier detection
00
hex
…FF
hex
…
…
…
00
hex
…FF
hex
67
Last byte of data carrier detection
00
hex
…FF
hex
68
1
Number of bytes (ASCII) high byte
'0'…'9'
…
…
…
'0'…'9'
73
1
Number of bytes (ASCII) low byte
'0'…'9'
74
1
USER-data
00
hex
…FF
hex
…
…
…
00
hex
…FF
hex
…
1
USER-data
00
hex
…FF
hex
Last byte
1
BCC
00
hex
…FF
hex
Data carrier data (EPC/TID)
Byte
Length
Command element
Value range
00
1
Length ECP/TID
00
hex
…3E
hex
01
1
Reserved
00
hex
02
1
EPC Data[1]
00
hex
…FF
hex
03
1
EPC Data[2]
00
hex
…FF
hex
04
1
EPC Data[3]
00
hex
…FF
hex
…
…
…
00
hex
…FF
hex
63
1
EPC Data[62]
00
hex
…FF
hex
Summary of Contents for BIS V-6107