BIS V-6108 PROFINET
Processor Unit
16
english
In project planning for PROFINET devices, a device is mapped as a modular system that
consists of a "BIS V-6108" header module and multiple data modules.
The device data required for project planning is stored in GSDML files (General Station
Description). The data modules of each read/write head, each IO-Link port and possible
additional modules are represented in the project planning software relative to their slot. The
GSDML file makes the possible data modules (inputs/outputs for the read/write heads and the
IO-Link port for various data widths) available. Appropriate data modules are assigned to a
specific slot for configuring the V-6108.
The "BIS V-6108" header module always has to be plugged in at slot 0.
The data modules for the 4 read/write heads can be plugged in at slots 1 to 4. Depending on
use, an IO-Link port, a standard I/O, an IO-Link data module or an SIO module can be plugged
in at slot 5.
Slot
Module
Function
0
BIS V-6108 header module
Parameter configuration, no process data
1
Read/write head
Parameter configuration and process data
2
Read/write head
3
Read/write head
4
Read/write head
5
IO-Link port pin 4
IO-Link data modules of various data width or
configurable as a standard input port
6
Communication status
Slots for optional additional modules
7
Sensor short circuit
8
Actuator overvoltage
9
Input pin 4
10
Output pin 4
11
Restart Pin 4
6.1 Configuration
GSDML file
6
Startup