BIS V-6108 PROFINET
Processor Unit
48
english
Command Identifier 41
hex
: Unselect (Undo a Data Carrier Selection)
The Unselect command undoes one data carrier selection that was carried out with the Select
command. If a selection is not active, the status will remain unchanged.
Subaddress
Meaning
Description of Function
00
hex
1st Bit Header
01
hex
Command Identifier 41
hex
: Unselect (Undo the data carrier selection).
…
None
No meaning
Last byte
2nd Bit Header
If the 1st and 2nd bit headers match, the data is valid.
Input Buffer: Status Message
Subaddress
Meaning
Description of Function
00
hex
1st Bit Header
01
hex
Status code
Provides information on the status of a query.
…
None
No meaning
Last byte
2nd Bit Header
If the 1st and 2nd bit headers match, the data is valid.
Specific
commands for
BIS VU read/write
heads
7
Device Functions