www.balluff.com
BIS V-6108 PROFINET
Processor Unit
67
english
7
Device Functions
Note
The
TID
memory area is inherently read-only regardless of the Lock Status and can
only be read.
Lock Status of the
Reserved
memory area (
Access
Password and
Kill
Password)
Lock
Permalock
Lock Status
0
0
Read and Write:
No Password
0
1
Read and Write:
No Password
(State can no longer be changed)
1
0
Read and Write:
Access Password
1
1
Read and Write:
Not Possible
(State can no longer be changed)
Subaddress
Meaning
Description of Function
00
hex
1st Bit Header
01
hex
Command Identifier 57
hex
: Lock.
02
hex
Mask[0]
03
hex
Mask[1]
04
hex
Action[0]
05
hex
Action[1]
…
None
No meaning
Last byte
2nd Bit Header
If the 1st and 2nd bit headers match, the data is valid.
Input Buffer: Status Message
Subaddress
Meaning
Description of Function
00
hex
1st Bit Header
01
hex
Status code
Provides information on the status of a query.
…
None
No meaning
Last byte
2nd Bit Header
If the 1st and 2nd bit headers match, the data is valid.
Specific
commands for
BIS VU read/write
heads