www.balluff.com
BIS V-6108 PROFINET
Processor Unit
19
english
Slot 0, Subslot 1
Index Byte Bit
Length
Contents
Values
Default
1
0
0
1 Bit
Global diagnosis
0/1
0
0
4
1 Bit
HMI read only
0/1
0
0
5
1 Bit
LEDs off
0/1
0
2
0
0
1 byte
IO-Link port function
0/1/3/4/5/6
0
3
1
0
1 byte
IO-Link safe state
0/1
0
Slot 1 to 4, subslot 1 in each case
Index Byte Bit
Length
Contents
Values
Defa u lt
1
0
0
1 Bit
CRC
0/1
0
0
1
1 Bit
Dynamic mode*
0/1
0
0
2
1 Bit
Type serial number
0/1
0
0
3
1 Bit
Slow tag detection* 0/1
0
0
4
1 Bit
Low antenna
power*
0/1
0
0
5
1 Bit
Head LEDs off
0/1
0
1
0
1 byte
UID Compare
Count (only BIS
VL-3 _ _)
1…7
2
2
0
1 byte
Tag type
Data Carrier Type
1
0:
10:
11:
20:
21:
22:
30:
31:
All data carriers in the
series used
(e.g. BIS VM) are
recognized*
Mifare
ISO 15693
EM4x02
Hitag1
HitagS
BIS C 32 byte
BIS C 64 byte
2
0
0
16 bits
Process data length 8…254
Fixed
per
module
* Not for read/write heads BIS VU-_ _
6.2 Parameter
Configuration
Device Parameter
RFID port
parameter
6
Startup