www.balluff.com
BIS V-6108 PROFINET
Processor Unit
51
english
Command Identifier 44
hex
: Read from TID
Reads the TID memory area of a data carrier that was previously selected with the Select
command.
In Single-Tag mode, that is, if only one data carrier is located in front of the active read/write zone
antenna, then the Select command can be disregarded. The
Read from EPC
command will be
automatically executed on the data carrier that is located in front of the antenna.
Note
If the order is executed without the preceding Select and more than one data carrier
is located in front of the antenna, the command will then be acknowledged with the
Multiple-Tags status code.
The length of the TID data field is defined by a parameter setting.
Subaddress
Meaning
Description of Function
00
hex
1st Bit Header
01
hex
Command Identifier 44
hex
: Read from TID.
…
None
No meaning
Last byte
2nd Bit Header
If the 1st and 2nd bit headers match, the data is valid.
If execution is successful, the response is passed to the input buffer in the following format:
Subaddress
Meaning
Description of Function
00
hex
1st Bit Header
01
hex
TID Data
Transmission of TID data that was read from the data
carrier.
…
TID Data
Transmission of TID data that was read from the data
carrier.
…
None
No meaning
Last byte
2nd Bit Header
Valid data is present if the 1st and 2nd bit strings
match.
or
Input Buffer: Status Message
Subaddress
Meaning
Description of Function
00
hex
1st Bit Header
01
hex
Status code
Provides information on the status of a query.
…
None
No meaning
Last byte
2nd Bit Header
If the 1st and 2nd bit headers match, the data is valid.
Specific
commands for
BIS VU read/write
heads
7
Device Functions