www.balluff.com
BIS V-6108 PROFINET
Processor Unit
63
english
7
Device Functions
Upon successful execution (AE = 1, AF = 0), the number of written data carriers is transmitted
into the input buffer in the following format:
Subaddress
Meaning
Description of Function
00
hex
1st Bit Header
AE = 1, AF = 0: Command finished.
01
hex
No. of tags
Number of detected tags.
02
hex
Number of
Successfully
Written Data
Carriers
0…255
…
None
No meaning
Last byte
2nd Bit Header
If the 1st and 2nd bit headers match, the data is valid.
or
Input Buffer: Status Message
Subaddress
Meaning
Description of Function
00
hex
1st Bit Header
AF = 1: Status message
01
hex
Status code
Provides information on the status of a query.
…
None
No meaning
Last byte
2nd Bit Header
If the 1st and 2nd bit headers match, the data is valid.
Specific
commands for
BIS VU read/write
heads