BIS V-6108 PROFINET
Processor Unit
84
english
7
Device Functions
12. Bulk Write (only BIS VU)
Write to all data carriers that are located in front of the antenna. Write 16 bytes starting at data
carrier address 3.
Control
Identification System
1.
Process output buffer
(note sequence):
2.
Process Input Buffer
(note sequence):
01
hex
Command designator 54
hex
00
hex
/0F
hex
Set AA bit, invert TO bit
02
hex
Start address 03
hex
03
hex
Start address 00
hex
04
hex
No. of bytes 10
hex
05
hex
No. of bytes 00
hex
06
hex
Subset Type 00
hex
07
hex
Max Tags FF
hex
00
hex
/0F
hex
Set AV Bit
3.
Process output buffer:
4a. Process output buffer:
01…0E
hex
Enter first 14 bytes
01…0E
hex
Copy first 14 bytes
00
hex
/0F
hex
Invert TI bit
4b. Process input buffer:
00
hex
/0F
hex
Invert TO bit
5.
Process output buffer:
6a. Process output buffer:
01…02
hex
Enter the last 2 bytes
01…02
hex
Copy last 2 bytes
00
hex
/0F
hex
Invert TI bit
6b. Process input buffer:
01
hex
Enter the number of tags
found
02
hex
Enter the number of
successfully written tags
00
hex
/0F
hex
Set AE bit
7.
Process input buffer:
8.
Process input buffer:
01
hex
Copy the number of tags
found
00
hex
/0F
hex
Reset AA and AE bits
02
hex
Copy the number of
successfully written tags
Process output buffer:
00
hex
/0F
hex
Reset AV bit
Examples