background image

Balluff Network Interface / CC-Link BNI-CCL-104/202/302/305-100-Z001 

   

1 Notes to the User 
1.1   

About this guide 

1.2   

Structure of the guide 

1.3   

Typgraphical Conventions 

1.4   

Symbols 

1.5   

Abbreviations 

 
2 Safety 
2.1 

Intended Use 

2.2 

General Safety Notes 

2.3 

Meaning of the warnings 

 
3 Getting Started 
3.1 

Connection overview 

3.2 

Mechanical connection 

3.3 

Supply voltage connection 

3.4 

CC-Link connection 

3.5 

Connecting sensors / actuators 

 
4 Technical data 
4.1 

Dimensions 

4.2 

Mechanical Data 

4.3 

Operating conditions 

4.4 

Electrical Data 

4.5 

CC-Link Port 

4.6 

Function Indicators 

 
5 Remote signals 
5.1 

Port overview 

5.2 

Remote I/O / Data mapping 

5.2.1 

BNI CCL-104-100-Z001 

5.2.2 

BNI CCL-202-100-Z001 

10 

5.2.3 

BNI CCL-302-100-Z001 

11 

5.2.4 

BNI CCL-305-100-Z001 

12 

5.3 

Remote register allocation 

12 

5.4 

Error Code register 

12 

5.5 

Port sensor diagnostic register 

13 

5.6 

Channel actuator diagnostic register 

13 

5.7 

Port direction register 

13 

5.8 

Display register 

13 

5.9 

Port direction settings 

13 

 
6 Display 
6.1 

General 

14 

6.2 

Default address 

14 

6.3 

Display information 

14 

6.4 

Menu structure 

14 

6.5 

Edit mode 

15 

 
7 Included Material 
7.1 

Included Material 

15 

 
 
Appendix 
 

Ordercode / order informations 

15 

 

Summary of Contents for BNI CCL-104-100-Z001

Page 1: ...BNI CCL 104 100 Z001 BNI CCL 202 100 Z001 BNI CCL 302 100 Z001 BNI CCL 305 100 Z001 User Manual...

Page 2: ...4 3 Operating conditions 7 4 4 Electrical Data 7 4 5 CC Link Port 8 4 6 Function Indicators 8 5 Remote signals 5 1 Port overview 9 5 2 Remote I O Data mapping 9 5 2 1 BNI CCL 104 100 Z001 9 5 2 2 BNI...

Page 3: ...4 Technical data for the device 1 3 Typographical Conventions The following typographical conventions are used in this guide Syntax Numbers Decimal numbers are shown without additional indicators e g...

Page 4: ...g the appropriate measures before using The device may be operated only using an approved power supply see 0 Technical Data Only approved cables may be used Operations and testing The operator is resp...

Page 5: ...interfaces are shown in the following chapters 1 Mounting hole 2 CC Link Bus Input 3 Display 4 Power supply IN 5 Standard input Port X4 X5 6 Standard Input Port X6 X7 7 Standard Output Port Y4 Y5 8 S...

Page 6: ...ommunication supply 5 24V Actuator supply Power Out 7 8 Mini Change 5 pin female PIN Signal Description 1 0 V Actuator supply 2 0 V Sensor and bus communication supply 3 FE Function Ground 4 24V Senso...

Page 7: ...A Line blue 3 5 Connecting sensors actuators 8 I O ports are provided for connecting actuators and sensors Standard I O port M12 A coded female Input Output Combined Inputs Outputs PIN Function Functi...

Page 8: ...nput ports Output ports M12 A coded 8 x female Dimensions W x H x D in mm 68 x 224 x 30 9 Mounting type 2 hole screw mount Ground strap attachment M4 Weight Approx 580gr 4 3 Operating conditions Opera...

Page 9: ...s Status LED LED Indicator Function LED 1 Green Red Module Status LED 2 Green Red UA Power supply under voltage LED 6 Green Communication status LED 7 Red Communication error LED indicators input port...

Page 10: ...Port 3 Pin 4 RXn7 Port 3 Pin 2 RXn8 Port 4 Pin 4 RXn9 Port 4 Pin 2 RXnA Port 5 Pin 4 RXnB Port 5 Pin 2 RXnC Port 6 Pin 4 RXnD Port 6 Pin 2 RXnE Port 7 Pin 4 RXnF Port 7 Pin 2 RX n 1 0 to RX n 1 7 Unus...

Page 11: ...4 RYn2 Port 2 Pin 4 RXn3 Port 3 Pin 4 RYn3 Port 3 Pin 4 RXn4 Port 4 Pin 4 RYn4 Port 4 Pin 4 RXn5 Port 5 Pin 4 RYn5 Port 5 Pin 4 RXn6 Port 6 Pin 4 RYn6 Port 6 Pin 4 RXn7 Port 7 Pin 4 RYn7 Port 7 Pin 4...

Page 12: ...in 4 RXn7 Port 3 Pin 2 RYn7 Port 3 Pin 2 RXn8 Port 4 Pin 4 RYn8 Port 4 Pin 4 RXn9 Port 4 Pin 2 RYn9 Port 4 Pin 2 RXnA Port 5 Pin 4 RYnA Port 5 Pin 4 RXnB Port 5 Pin 2 RYnB Port 5 Pin 2 RXnC Port 6 Pin...

Page 13: ...d RX n 1 8 Initial data processing request flag RY n 1 8 Initial data processing request flag RX n 1 9 Initial data setting completion flag RY n 1 9 Initial data setting completion flag RX n 1 A Error...

Page 14: ...10 9 8 7 6 5 4 3 2 1 0 P7 P2 P7 P4 P6 P2 P6 P4 P5 P2 P5 P4 P4 P2 P4 P4 P3 P2 P3 P4 P2 P2 P2 P4 P1 P2 P1 P4 P0 P2 P0 P4 Pn 0 Input Pm 1 Output 5 8 Display register 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0...

Page 15: ...the communication speed is set directly on the BNI CCL devices 6 2 Default settings Address 3 Communication speed 625kbps 6 3 Display informations 6 4 Menu structure Start up screen 2 sec address win...

Page 16: ...peed is set directly on the BNI CCL devices push scroll to the next screen long push fast scroll is activated long push S for 3 seconds edit mode is activated display informations flashing leave the e...

Page 17: ...CC Link BNI CCL 104 202 302 305 100 Z001 www balluff com 16 7 Included Material 7 1 Included Material The BNI CCL consists of the following components IO block 4 blind plugs M12 Ground strap Screw M4...

Page 18: ...odule max 16 Inputs Outputs 305 IP 67 Input module 8 Inputs 8 Outputs Variant 100 Display version Mechanical version Z001 Die cast zinc housing Material 1 Balluff housing version Bus In 1 x M12x1 inte...

Page 19: ...Balluff Network Interface CC Link BNI CCL 104 202 302 305 100 Z001 www balluff com 18...

Page 20: ...104 202 302 305 100 Z001 www balluff com 19 www balluff com Balluff GmbH Schurwaldstrasse 9 73765 Neuhausen a d F Germany Tel 49 7158 173 0 Fax 49 7158 5010 balluff balluff de n www balluff com Nr 870...