8
english
4
Product description (continued)
4.2
Function
The gateway sends data from a BCM sensor via mobile
radio (LTE, 2G) to a cloud (MS Azure). The interface of the
BCM to the gateway is an IO-Link. The gateway can be
operated via an external power supply unit with 24 V, as
well as with rechargeable batteries.
The gateway is part of the
Portable Monitoring System
for
quick and easy monitoring of machines and plants. All
components required for condition monitoring are
integrated: BCM sensor, mobile gateway and the
visualization software (see
Thanks to the rechargeable batteries integrated in the
gateway and data transmission via mobile radio, data can
be recorded flexibly and portably. In addition, the data
stored in the cloud can be accessed from anywhere and
the plants can thus be monitored remotely.
4.3
Operating and display elements
LED: Energy
Signal
Meaning
Green (static)
24 V supply voltage and battery
voltage OK.
Flashing green
24 V supply voltage OK and
charge batteries.
Blue (static)
Device operating in battery mode
only and battery voltage is OK.
Blue flashing
Device in standby and battery is
charging.
Red flashing
Low battery voltage (< 20 %)
Tab. 4-1: LED: Energy
LED: Data
Signal
Meaning
Green (static)
Device is in operation and
transmitting measurement values.
Yellow, flashing
Standby mode
Blue
Device is in operation, sensor not
connected or connected sensor
is not supported.
Blue flashing
Establishing connection to the
cloud.
Red
No mobile radio connection
Red flashing
Error
White flashing
Firmware update in progress. Do
not switch off the device.
Tab. 4-2: LED: Data
On/Off switch
Function
Operation
Turn-on
►
Press button briefly
Shut down
►
Press button longer
Tab. 4-3: On/Off switch
4.4
Part label
BNI00FJ
BNI EGW-566-002-K082
SN: XXXXXXXXXX
Device ID: XXXXXXXXXX
1)
2)
4)
3)
1)
Order code
2)
Serial number
3)
Type
4)
Device ID
Fig. 4-2: Part label (detail. example)
BNI EGW-566-002-K082
Mobile Gateway
Summary of Contents for BNI EGW-566-002-K082
Page 1: ...BNI EGW 566 002 K082 deutsch Betriebsanleitung english User s guide...
Page 2: ...www balluff com...
Page 3: ...BNI EGW 566 002 K082 Betriebsanleitung deutsch...
Page 4: ...www balluff com...
Page 17: ...BNI EGW 566 002 K082 User s Guide english...
Page 18: ...www balluff com...
Page 31: ......