5
3
Getting Started
3.2
Mechanical
connection
The BNI IOL modules are attached using 3 M4 screws (Item 1, Fig. 3-1/3-2).
3.3
Electrical
connection
The Sensor Hub modules require no separate supply voltage connection.
Power is provided through the IO-Link interface by the host IO-Link Master.
3.4
Function ground
The modules are provided with a ground terminal.
Connect Sensor Hub module to the ground terminal.
Note!
The FE connection from the housing to the machine must be low-impedance
and as short as possible.
3.5
IO-Link
connection
The IO-Link connection is made using an M12 connector (A-coded, male).
IO-Link (M12, A-coded, male)
Pin
Function
1
Supply voltage, +24 V, max. 1.6 A
2
-
3
GND, reference potential
4
C/Q, IO-Link data transmission channel
Connection protection ground to FE terminal, if present.
Connect the incoming IO-Link line to the Sensor Hub.
Note!
A standard sensor cable is used for connecting to the host IO-Link Master.