Integration 

 

(5) Integration to 
the ProfiNet 
network 

 

 

 

 

(6) Scanning the 
system 

  Durch das Einscannen werden alle angeschlossenen Profinet Teilnehmer erkannt und eine 

Auflistung erzeugt. Module ohne Netzwerkadresse werden identifiziert, eindeutig 
selektierbar über die MAC Adresse. 
 

 

 

Browse 

– Identification 

of all connected 
ProfiNet devices 

Selection of the module 
that has no  IP address 

Summary of Contents for BNI PNT-502-001-Z002

Page 1: ...BNI PNT 502 001 Z002 IP67 Modules Profinet IO Link Master User s Guide...

Page 2: ...5 Profinet Interface 5 I O Port 6 IO Link Port 6 4 Technical data 7 4 1 Dimensions 7 4 2 Mechanical data 7 4 3 Electrical data 7 4 4 Operating conditions 7 4 5 Function indicators 8 Module LEDs 8 I O...

Page 3: ...Actions Action instructions are indicated by a preceding triangle The result of an action is indicated by an arrow Action instruction 1 Action result Action instruction 2 Procedures can also be shown...

Page 4: ...take precautionary measures accordingly The device must be powered only using an approved power supply see chapter 4 Technical data Only approved cable may be used Operating and testing The operator...

Page 5: ...rofinet Port2 3 Power supply IN 4 I O Port 1 5 I O Port 3 6 I O IO Link Port 5 7 I O IO Link Port 7 8 I O IO Link Port 6 9 I O IO Link Port 4 10 Symbol IO Link Port 11 I O Port 2 12 Port LED 13 E A Po...

Page 6: ...y 0 V 3 Funktionserde FE 4 Bus Sensor power supply 24 V 9ADC 5 Actuator power supply 24 V 9A DC Note Provide sensor bus power and actuator power from separate power sources if possible Total current 9...

Page 7: ...must be fitted with cover caps to ensure IP67 protection rating Note For the digital sensor inputs follow the input guideline per EN61131 2 type 2 IO Link Port IO Link Port M12 A coded female Pin Func...

Page 8: ...Ports Connector M12 A coded 8x female Enclosure rating per IEC 60529 IP 67 only when plugged in and threaded in Weight 800 g 4 3 Electrical data Betriebsspannung 18 30 2 V DC per EN 61131 2 Restwellig...

Page 9: ...f ProfiNet communication activ at Port PN2 ProfiNet communication not active at Port PN2 ERR Red Off Error module No error I O Port LEDs LED State Function 0 Off Yellow Red Input output signal at Pin...

Page 10: ...example with the STEP 7 Engineering Tool 3 Including the module to Configuration 4 Setting the object properties 5 Naming of the device 6 Configuration of the Ethernet address 7 Integration to the Pro...

Page 11: ...Balluff Network Interface Profinet BNI PNT 502 001 Z002 www balluff com 10 5 Integration 3 Naming of the device 4 Configuration of the Ethernet address...

Page 12: ...ch das Einscannen werden alle angeschlossenen Profinet Teilnehmer erkannt und eine Auflistung erzeugt Module ohne Netzwerkadresse werden identifiziert eindeutig selektierbar ber die MAC Adresse Browse...

Page 13: ...rk Interface Profinet BNI PNT 502 001 Z002 www balluff com 12 5 Integration 7 Integration by device name 8 Assumption of the properties MAC Address of the Module Assignment by Ip address Assignment by...

Page 14: ...ork Interface Profinet Function 502 IP67 IO Module 4 x IO Link ports 4 x Standard I OPorts Variants 001 Standard Ausf hrung Mechanical version Z014 Die cast zinc housing Material 1 Balluff housing ver...

Page 15: ...www balluff com 14 Notes...

Page 16: ...www balluff com www balluff com Balluff GmbH Schurwaldstrasse 9 73765 Neuhausen a d F Germany Tel 49 7158 173 0 Fax 49 7158 5010 balluff balluff de Nr 869943 E Edition 1101 Subject to modification...