Primary Device Functions (continued)
5.2
Device Discovery
5.2.1 Description
With the
Device Discovery
function, an IO-Link device can
be found again by starting signaling on the LED of the
device by means of a system command.
5.2.2 ISDU
Name
Index
Subindex
Access
Length
Data Type
Data
Storage
Default
Device Discovery Timeout
0x00FE (254)
0
R/W
2 bytes
INT
Yes
1
Tab. 5-2: Device detection – ISDU
Device Discovery Timeout
The
Device Discovery Timeout
parameter sets the duration
of the Device Discovery signal that is displayed via LEDs.
The value is specified minutes. The value range from 0 to
30 minutes is allowed. If the parameter is set to 0, the
Device Discovery signal is deactivated. The parameter is
reset by
Application Reset
and
Factory Reset
(also see
5.2.3 System Commands
Command Value Device Action
0xAF (175)
Start Device Discovery
Tab. 5-3: Device detection – System Commands