6.6.7 Temperature
The following temperature values are output by the BTL as
signed 8-bit values with the unit °C:
– Current temperature (subindex 1)
– Maximum temperature since power-up (subindex 2)
– Minimum temperature since power-up (subindex 3)
– Maximum temperature over the entire lifetime
(subindex 4)
– Minimum temperature over the entire lifetime
(subindex 5)
The temperature sensor detects the
temperature within the BTL. This is always
higher than the ambient temperature.
6.6.8 IO Link Variant config
This parameter should only be used for initial
parameterization of another device variant.
Using this parameter, the IO-Link variant or device
configuration can be adjusted (see section
on page 14). Access takes place via subindex 0
with an 8-bit unsigned integer value.
The following device variants can be selected:
Value Product name
Device ID Product ID
1)
Transfer rate
Amount of process
data device – master
Min. cycle
time
0x00
BTL6-U100-…
0x030200
BTL6ABYZIOL000
COM3
0x83 (4 bytes)
0x0A (1 ms)
0x01
BTL6-U101-…
2)
0x030201
BTL6ABYZIOL001
COM3
0x87 (8 bytes)
0x0A (1 ms)
0x02
BTL6-U102-…
0x030202
BTL6ABYZIOL002
COM3
0x8F (16 bytes)
0x0F (1.5 ms)
0x03
BTL6-U103-…
0x030203
BTL6ABYZIOL003
COM3
0x9F (32 bytes)
0x14 (2 ms)
0x04
BTL6-U104-…
0x030204
BTL6ABYZIOL004
COM2
0x83 (4 bytes)
0x28 (4 ms)
0x05
BTL6-U105-…
0x030205
BTL6ABYZIOL005
COM2
0x87 (8 bytes)
0x3C (6 ms)
0x06
BTL6-U106-…
0x030206
BTL6ABYZIOL006
COM2
0x8F (16 bytes)
0x47 (9.2 ms)
0x07
BTL6-U107-…
0x030207
BTL6ABYZIOL007
COM2
0x9F (32 bytes)
0x60 (14.4 ms)
1)
ABYZ stands for the respective housing style
2)
Standard variant, see Tab. 6-1
Tab. 6-8: Parameters of the different
BTL6-U10_-… IO-Link device variants
This parameter changes the device’s basic
communication settings. Changing parameters
automatically triggers a device restart; the
corresponding error messages in the superior
system must be accepted.
The parameter is not reset to factory settings
via the
Factory Reset
Due to the special functionality, the parameter is not listed
in the IO device description (IODD) and is not intended for
data storage. For operation in a special IO-Link variant,
Compatibility Mode
is supported between the individual
page 12).
6
IO-Link interface (continued)
BTL6-U101-M _ _ _ _ -A/B/Y/Z-S4
Magnetostrictive Linear Position Sensor – Rod Style
Summary of Contents for BTL6-U101-M****-A-S4 series
Page 2: ...www balluff com...
Page 3: ...BTL6 U101 M_ _ _ _ A B Y Z S4 Betriebsanleitung deutsch...
Page 4: ...www balluff com...
Page 27: ...BTL6 U101 M_ _ _ _ A B Y Z S4 User s Guide english...
Page 28: ...www balluff com...
Page 51: ...BTL6 U101 M_ _ _ _ A B Y Z S4 Notice d utilisation fran ais...
Page 52: ...www balluff com...
Page 75: ...BTL6 U101 M_ _ _ _ A B Y Z S4 Manuale d uso italiano...
Page 76: ...www balluff com...
Page 99: ...BTL6 U101 M_ _ _ _ A B Y Z S4 Manual de instrucciones espa ol...
Page 100: ...www balluff com...
Page 123: ......