8
english
4
Installation and connection (continued)
4.2
Electrical connection
The BTL is connected via a S115 connector (see
Accessories on page 14).
PIN
Color
BTL6‑V11V‑... interface
1
—
—
Not used
1)
2
OG/WH Orange/
white
Tx+
3
OG
Orange
Tx-
4
—
—
Not used
1)
5
GN/WH Green/white Rx+
6
BU
Blue
GND
2)
7
BN
Brown
+24 V
8
GN
Green
Rx-
1)
Unassigned leads can be connected to the GND on the control side but
not to the shield.
2)
Reference potential for supply voltage and EMC-GND.
Tab. 4-2: Pin assignment of S115 connector
Fig. 4-4: Pin assignment of S115 connector (view from above on
transducer plug)
4.3
Shielding and cable routing
Defined ground!
The transducer and the control cabinet must be
at the same ground potential.
Shielding
To ensure electromagnetic compatibility (EMC), observe
the following:
– Connect the transducer and controller using a shielded
cable.
Shielding: Copper filament braided, at least 85%
coverage
– Horizontally connect the shield in the connector to the
plug housing.
Magnetic fields
The position measuring system is a magnetostrictive
system. It is important to maintain adequate distance
between the transducer and strong, external magnetic
fields.
Cable routing
Do not route the cable between the transducer, controller,
and power supply near high voltage cables (inductive stray
noise is possible).
Cable length
The maximum cable length when using CAT5e cables is
100 m.
BTL6-V11V-M _ _ _ _ -A1-S115
Micropulse AT Transducer in round profile housing
Summary of Contents for BTL6-V11V-M Series
Page 1: ...BTL6 V11V M _ _ _ _ A1 S115 Betriebsanleitung deutsch ...
Page 17: ...BTL6 V11V M _ _ _ _ A1 S115 User s Guide english ...
Page 18: ...www balluff com ...
Page 34: ...BTL6 V11V M _ _ _ _ A1 S115 Manual de instrucciones español ...
Page 35: ...www balluff com ...
Page 51: ...BTL6 V11V M _ _ _ _ A1 S115 Notice d utilisation français ...
Page 52: ...www balluff com ...
Page 68: ...BTL6 V11V M _ _ _ _ A1 S115 Manuale d uso italiano ...
Page 69: ...www balluff com ...