www.balluff.com
23
english
11.1 Accuracy
The specifications are typical values for BTL7-A/C/E/G... at
24 V DC and room temperature, with a nominal length of
500 mm in conjunction with the BTL-P-1013-4R,
BTL-P-1013-4S, BTL-P-1012-4R or BTL-P-1014-2R
magnet.
The BTL is fully operational immediately, with full accuracy
after warm-up.
For special versions, other technical data may
apply.
Special versions are indicated by the suffix -SA
on the part label.
Repeat accuracy
Voltage, typical
Current, typical
±10 µm
±5 µm
Sampling rate
Dependent on nominal length
At nominal length
=
500 mm
250 µs to 5.7 ms
500 µs
Non-linearity at
Nominal length
≤
500 mm
Nominal length > 500 to
≤
5500 mm
Nominal length >
5500 mm
±50 µm
±0.01% FS
±0.02% FS
Temperature coefficient
1)
≤
30 ppm/K
Max. detectable speed
10 m/s
11.2 Ambient conditions
2)
Operating temperature
-
40°C to +85°C
Operating temperature for UL
(only BTL-…-KA…)
max. +80°C
Storage temperature
-
40°C to +100°C
Relative humidity
< 90%, non-con-
densing
Rod pressure rating
(when installed in hydraulic
cylinders)
For Ø 8 mm
< 250 bar
For Ø 10.2 mm
< 600 bar
Shock rating
per EN 60068-2-27
3)
150 g/6 ms
Continuous shock
per EN 60068-2-29
3)
150 g/2 ms
Vibration
per EN 60068-2-6
3)
(note resonant frequency of
the rod)
20 g, 10 to 2000 Hz
Degree of protection per
IEC 60529
Connector (when attached)
IP 67
Cable
IP 68
3)
11.3 Supply voltage (external)
Voltage, stabilized
4)
:
BTL7-_1_ _-...
BTL7-_5_ _-...
20 to 28 V DC
10 to 30 V DC
Ripple
≤
0.5 V
ss
Current draw (at 24 V DC)
≤
150 mA
Inrush current
≤
500 mA/10 ms
Reverse polarity protection
5)
Up to 36 V
Overvoltage protection
Up to 36 V
Dielectric strength
(GND to housing)
500 V AC
11.4 Output
BTL7-A… Output voltage
Load current
0 to 10 V and 10 to 0 V
≤
5 mA
BTL7-C… Output current
Load resistance
0 to 20 mA / 20 to 0 mA
≤
500 ohms
BTL7-E… Output current
Load resistance
4 to 20 mA / 20 to 4 mA
≤
500 ohms
BTL7-G… Output voltage
Load current
-
10 to 10 V and 10 to
-
10 V
≤
5 mA
Short circuit resistance
Signal cable to 36 V
Signal cable to GND
11.5 Input
Programming inputs La, Lb:
High-active
BTL7-_1_ _-...
BTL7-_5_ _-...
20 to 28 V DC
10 to 30 V DC
Overvoltage protection
up to 36 V
1)
Nominal length = 500 mm, magnet in the middle of the measuring range
2)
For
: Use in enclosed spaces and up to a height of 2000 m above sea
level.
3)
Individual specifications as per Balluff factory standard
4)
For
: The transducer must be externally connected via a limitedenergy
circuit as defined in UL 61010-1, a low-power source as defined in
UL 60950-1, or a class 2 power supply as defined in UL 1310 or
UL 1585.
5)
A prerequisite is that no current can flow between GND and 0 V in the
event of polarity reversal.
11
Technical data
BTL7-A/C/E/G_ _ _-M_ _ _ _-A/B/Y/Z(8)-S32/S115/S135/S140/KA_ _/FA_ _
Micropulse Transducer - Rod Style
Summary of Contents for BTL7-A Series
Page 2: ...www balluff com...
Page 33: ...www balluff com...
Page 64: ...www balluff com...
Page 95: ...www balluff com...
Page 126: ...www balluff com...