www.balluff.com
15
english
Ignition protection
“nA” and “tb”
6.3
Calibration procedure overview
6.3.1 Teach-in
The factory set null point and end point is replaced by a
new null point and end point. The null point and end point
can be set separately, the output gradient changes.
The detailed procedure for teach-in is described
on page 17.
Steps:
►
Move magnet to the new null position.
►
Read new null point by activating the programming
inputs.
⇒
The current end point remains the same.
New null point
Before
After
Fig. 6-2: Reading new null point
6
Calibration procedure (continued)
►
Move magnet to the new end position.
►
Read new end point by activating the programming
inputs.
⇒
The current null point remains the same.
New end point
Before
After
Fig. 6-3: Reading new end point
Only with BTL7-C/E…:
►
The gradient of the current output can be inverted by
activating the programming inputs.
⇒
For example, a rising output gradient is changed to
a falling gradient. The voltage outputs are not
inverted.
BTL7-A/C/E/G5 _ _ -M _ _ _ _ -K(8)-NEX-SR32/K_ _ _
Micropulse Transducer - Rod Style
Summary of Contents for BTL7-A5 Series
Page 2: ...www balluff com ...