www.balluff.com
25
english
Ignition protection
“nA” and “tb”
12
Type code breakdown
BTL7 - E 5 0 0 - M0500 - K - NEX - SR32
Micropulse transducer
Interface:
A = Analog interface, voltage output 0…10 V
G = Analog interface, voltage output −10…10 V
C = Analog interface, current output 0…20 mA
E = Analog interface, current output 4…20 mA
Supply voltage:
5 = 10…30 V DC
Output gradient:
00 = Rising (e.g. C_00 = 0…20 mA); only with BTL7-C/E
10 = falling (e.g. A_10 = 10…0 V and 0…10 V); only with BTL7-A/G
70 = Falling (e.g. C_70 = 20…0 mA); only with BTL7-C/E
Nominal length (4-digit):
M0500 = Metric specification in mm, nominal length 500 mm
(M0025…M1016: K8)
(M0025…M5500: K)
Rod version, fastening:
K = Flange with 6 holes, O-ring, rod diameter 10.2 mm
K8 = Flange with 6 holes, O-ring, rod diameter 8 mm
Electrical connection, radial:
SR32 = 8-pin, M16 plug per IEC 130-9
K05 =
Cable, 5 m (PUR)
BTL7-A/C/E/G5 _ _ -M _ _ _ _ -K(8)-NEX-SR32/K_ _ _
Micropulse Transducer - Rod Style
Summary of Contents for BTL7-A5 Series
Page 2: ...www balluff com ...