www.balluff.com
21
english
9
Type code breakdown
BTL7 - A 5 0 4 - M0500 - TB2 - S32
Micropulse transducer
Analog interface:
A = Voltage output 0 to 10 V or 10 to 0 V (factory setting)
C = Current output 0 to 20 mA or 20 to 0 mA (factory setting)
E = Current output 4 to 20 mA or 20 to 4 mA (factory setting)
G = Voltage output −10 to 10 V or 10 V to −10 V (factory setting)
Supply voltage:
5 = 10 to 30 V DC
Output gradient:
04 = 1 output rising, configurable
05 = 1 output falling, configurable
Nominal length (4-digit):
M0500 = Metric specification in mm, nominal length 500 mm
BTL7-…-TB…/BTL7-…-TZ…: M0025…M7620
BTL7-…-TT…: M0025…M3250
Rod version, fastening:
TB2 = Metric mounting thread M18×1.5, O-ring, rod diameter 10.2 mm, dual redundant
TZ2 = 3/4”-16UNF thread, O-ring, rod diameter 10.2 mm, dual redundant
TT2 = Metric mounting thread M30×1.5, O-ring, rod diameter 21 mm, dual redundant
(Replacement for BTL5-...-T-2)
TB3 = Metric mounting thread M18×1.5, O-ring, rod diameter 10.2 mm, triple redundant
TZ3 = 3/4”-16UNF thread, O-ring, rod diameter 10.2 mm, triple redundant
TT3 = Metric mounting thread M30×1.5, O-ring, rod diameter 21 mm, triple redundant
(Replacement for BTL5-...-T-3)
Electrical connection:
S32 =
8-pin, M16 plug per IEC 130-9
S135 = 6-pin, M16 plug per IEC 130-9 (only for BTL7-…-TB…/ BTL7-…-TZ…)
KA05 = Cable, 5 m, PUR
FA05 = Cable, 5 m, PTFE
BTL7-A/C/E/G50_-M_ _ _ _ -T_2/3-S32/S135/KA_ _/FA_ _
Micropulse Transducer - Rod Style
Summary of Contents for BTL7-A50 Series
Page 2: ...www balluff com...
Page 25: ...www balluff com...
Page 48: ...www balluff com...
Page 71: ...www balluff com...
Page 94: ...www balluff com...