1
Intended use
The BTL7 Micropulse Transducer, together with a machine
controller (e. g. PLC), comprises a position measuring
system. It is intended to be installed into a machine or
system. Flawless function in accordance with the
specifications in the technical data is ensured only when
using original BALLUFF accessories. Use of any other
components will void the warranty.
Opening the transducer or non-approved use are not
permitted and will result in the loss of warranty and liability
claims against the manufacturer.
General safety notes
Installation
and
startup
may only be performed by
trained specialists with basic electrical knowledge.
The
operator
is responsible for ensuring that local safety
regulations are observed.
In particular, the operator must take steps to ensure that a
defect in the position measuring system will not result in
hazards to persons or equipment.
If defects and unresolvable faults occur in the transducer,
it should be taken out of service and secured against
unauthorized use.
Downloading further instructions
A complete user’s guide can be downloaded from the
Internet at
www.balluff.com
or requested via e-mail from
service@balluff.de
.
Dimensions and function
The transducer contains the waveguide which is protected
by an aluminum housing. A magnet is moved along the
waveguide. This magnet is connected to the system part
whose position is to be determined. The magnet defines
the position to be measured on the waveguide.
LED 1
Green
Normal function
Magnet is within the limits.
Red
Error
No magnet or magnet outside the limits.
LED 2
Off
Normal function
Valid Init signal.
Flashing red
Init error
Missing or invalid Init signal and LED 1 is off.
12
72
73
~80
~80
~250
~250
15
50
35
LED 1
LED 2
68
41
36.8
≤ 4
~23
max. 7
1) Unusable area
2) Not included in scope of delivery
1)
Nominal length =
Measuring range
Magnet
BTL5-P-3800-2
1)
Mounting clamps with insulating bushes
and ISO 4762 M5x22 cylinder-head screws,
max. tightening torque 2 Nm
2)
2)
BTL7…-S32
BTL7…-cable
Installation
NOTICE
Improper installation
Improper installation can compromise the function of the
transducer and result in damage.
►
For this reason, ensure that no strong electrical or
magnetic fields are present in the immediate vicinity
of the transducer.
►
The recommended spacing for the installation must
be strictly observed.
Any orientation is permitted. Mount the transducer on a
level surface of the machine using the provided mounting
clamps and cylinder-head screws. A sufficient number of
mounting clamps is supplied.
Groove
english
BTL7-P511 -M _ _ _ _ -P-S32/KA_ _
Micropulse Transducer in a Profile Housing
The CE Mark verifies that our products
meet the requirements of the current
EMC Directive.
File no.
E227256