www.balluff.com
17
english
8
Adjusting
NOTICE!
Interference in function
Adjustment while the system is running may result in
malfunctions.
►
Stop the system before performing adjustment.
Displayed values (example)
At 0…10 V
At 4…20 mA
Initial situation:
– Transducer with magnet within measuring range
5.39 V
9.15 mA
Activate adjusting
►
Activate
b
for at least 4 s.
> 4 s
b
2.00 V
6.00 mA
⇒
Indication for adjustment is displayed.
⇒
The current position value is displayed again once
the button is released.
5.39 V
9.15 mA
Set start point
►
Bring magnet to the new start point.
1.04 V
4.82 mA
►
Activate
a
for at least 2 s.
> 2 s
a
⇒
The new start point is set with the last valid start
value.
0.00 V
4.00 mA
Adjust start value
►
The start value can be changed using
a
and
b
.
The gradient of the curve changes (see page 15).
0.00 V
4.00 mA
0.90 V
7.20 mA
►
End calibration procedure: Briefly activate
a
and
b
simultaneously (< 1 s).
< 1 s
a
b
2.00 V
6.00 mA
⇒
Set position value is saved.
0.90 V
7.20 mA
For setting the end point, adjusting the end value,
and ending adjustment, see page 18.
Any of the individual steps for settings can be
selected. The adjustment process can be
ended at any time.
a
a
b
b
BTL7-A/C/E/G5 _ _ -M _ _ _ _ -H/W(8)-S32/S115/_ _ _
Micropulse Transducer - Rod Style
Summary of Contents for BTL7 Series
Page 1: ...Betriebsanleitung BTL7 A C E G5_ _ M_ _ _ _ H W 8 S32 S115 _ _ _ S 3 2 deutsch ...
Page 2: ...www balluff com ...
Page 28: ...User s Guide BTL7 A C E G5_ _ M_ _ _ _ H W 8 S32 S115 _ _ _ S 3 2 english ...
Page 29: ...www balluff com ...
Page 55: ...Manual de instrucciones BTL7 A C E G5_ _ M_ _ _ _ H W 8 S32 S115 _ _ _ S 3 2 español ...
Page 56: ...www balluff com ...
Page 82: ...Notice d utilisation BTL7 A C E G5_ _ M_ _ _ _ H W 8 S32 S115 _ _ _ S 3 2 français ...
Page 83: ...www balluff com ...
Page 109: ...Manuale d uso BTL7 A C E G5_ _ M_ _ _ _ H W 8 S32 S115 _ _ _ S 3 2 italiano ...
Page 110: ...www balluff com ...