www.balluff.com
7
english
3
Construction and function (continued)
3.3
LED display
Fig. 3-2: BTL7 LED displays
3.3.1 LED 1: BTL status
LED 1
Operating state
Green
Normal function
Magnet is within the limits.
Red
Error
No magnet or magnet outside the limits.
Tab. 3-1: LED 1
LED 2
(PROFINET
status)
LED 1
(BTL status)
LED 3
(Link/Activity
IN)
LED 4
(Link/Activity
OUT)
3.3.2 LED 2: PROFINET status (dual LED)
LED 2
Red
(Bus Failure)
Green
Meaning
Cause
Off
Off
No supply voltage
On
On
No bus connection with other
participants (no link)
Bus not connected
Master cannot be accessed or is switched off
Flashing
1)
On
Bus connection (link) available, but
the sensor is not involved in cyclic
data exchange.
Sensor is starting up, but parameterization has not yet been
completed.
Sensor has been incorrectly configured.
The sensor was assigned an incorrect station address and is thus
not accessible.
The desired configuration is not the same as the sensor
configuration.
Off
On
The sensor is involved in cyclic data
exchange.
1)
Flashing frequency is 0.5 Hz. The signal is shown for at least 3 s.
Tab. 3-2: LED 2
3.3.3 LED 3/LED 4: Link/Activity
LED 3/LED 4
Green
Status
Connection
On
Port open
Yes
Flashing
Requested by the master
to identify the device
Yes
Off
Port closed
No
Tab. 3-3: LED 3/4
BTL7-V50T-M _ _ _ _ -P-C003
Micropulse Transducer in a Profile Housing
Summary of Contents for BTL7-V50T-M-P-C003 Series
Page 1: ...BTL7 V50T M_ _ _ _ P C003 Betriebsanleitung deutsch...
Page 2: ...www balluff com...
Page 20: ...BTL7 V50T M_ _ _ _ P C003 User s Guide english...
Page 21: ...www balluff com...
Page 39: ...BTL7 V50T M_ _ _ _ P C003 Manual de instrucciones espa ol...
Page 40: ...www balluff com...
Page 58: ...BTL7 V50T M_ _ _ _ P C003 Notice d utilisation fran ais...
Page 59: ...www balluff com...
Page 77: ...BTL7 V50T M_ _ _ _ P C003 Manuale d uso Italiano...
Page 78: ...www balluff com...