249
www.balluff.com
BVS HS-Q Series
Standard Hand Held Barcode Reader
5
References
5.5.7 Multiple Labels
Ordering by
Code
Symbology
This feature Specifies the transmission ordering by symbology type, when Multiple Labels per
Frame is enabled.Up to six symbologies can be selected. Zeroes must be added to pad the string
to 12 characters if not using all six symbologies.
The labels are ordered first as specified in the output mask. Labels present in the volume but not
specified will be transmitted as unspecified symbologies in random order as allowed by the read-
ing time sequence. For each label decoded in the volume the reader signals the standard beeper
and LED indications.
To specify the symbology order:
1
Determine the symbologies and order you want to specify.
2
Use
to find the hex values for up to six symbologies.
3
Go to
and scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Pro-
gramming Mode.
4
Scan the barcode: “SELECT SYMBOLOGIES FOR MULTIPLE LABELS ORDERING”.
5
Scan the appropriate two alphanumeric characters from the keypad in
barcodes in this appendix to enter numbers as you would select digits/characters from a key-
pad.
, that represent the desired character/value in step 2 above.
6
Scan zeroes if needed to make a 12-character string.
7
When finished, scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming
Mode.
This completes the procedure. See
Table Multiple Labels Ordering by Code Symbology Examples
for some examples of how to set this feature.
Multiple Labels
Ordering by
Code
Symbology
Examples
shows the hex value associated with each symbology.
STEP ACTION
EXAMPLES
1
Desired symbology
Code 39
Data Matrix
Code 128
Aztec
2
24
0E
0C
4E
3
Scan ENTER/EXIT PROGRAMMING MODE
4
Scan SELECT SYMBOLOGIES FOR MULTIPLE LABELS ORDERING
5
Scan Two Characters
From
the barcodes in this
appendix to enter
numbers as you would
select digits/characters
from a keypad.
‘2’ and ‘4’
‘0’ and ‘E’
‘0’ and ‘C’
‘4’ and ‘E’
RESULT
0x240E0C4E0000
6