background image

265

www.balluff.com

BVS HS-Q Series
Standard Hand Held Barcode Reader

7

Appendix B: Standard Defaults

DATA FORMAT

Global Prefix/Suffix on page 57

No Global Prefix

Global Suffix = 0x0D 

(CR)

57

Global AIM ID on page 58

Disable

58

Set AIM ID Individually for GS1-128 on 
page 60

Enable

60

Label ID: Pre-Loaded Sets on page 61

EU Set

61

Individually Set Label ID on page 61

Disable

61

Case Conversion on page 67

Disable

67

Character Conversion on page 68

No Char Conversion

68

READING PARAMETERS

 on page 69Double Read Timeout on 
page 70

0.6 Second

69

Power On Alert on page 71

Power-up Beep

71

Good Read: When to Indicate on page 
71

After Decode

71

Good Read Beep Type on page 72

Mono

72

Good Read Beep Frequency on page 72

High

72

Good Read Beep Length on page 73

80 ms

73

Good Read Beep Volume on page 74

High

74

Good Read LED Duration on page 75

300 ms

75

READING FEATURES

Scan Mode on page 76

Trigger Single

76

Stand Mode Indication on page 77

Disable

77

Stand Operation on page 77

Switch to Stand 

Mode

77

Pick Mode on page 78

Disable

78

Stand Mode Sensitivity on page 78

Medium

78

Stand Mode Illumination Off Time on 
page 79

2 Seconds

79

Reading Active Time on page 79

5 Seconds

79

Stand Illumination Control on page 80

OFF

80

Flash On Time on page 80

10 = Flash is ON for 

1 Second

80

Flash Off Time on page 81

06 = Flash is OFF for 

600ms

81

Aiming Pointer on page 81

Enable

81

Parameter

Default

Your Setting

Page 
Number

Summary of Contents for BVS HS-Q Series

Page 1: ...Balluff BVS HS Q Family Standard Handheld Barcode Reader Operation Manual english...

Page 2: ...ument especially the Safety Notes section must be strictly observed This operator s manual must be carefully stored so that it is always available The information and illustrations in this operating m...

Page 3: ...em and Network Layouts 25 Stand Alone Layout 25 Connecting the Base when Security Pin is Enabled 25 Linking the Reader to a Base Station 26 RF Devices 26 BT Models only 26 Linking a BT Reader to a PC...

Page 4: ...cter 02 49 Intercode Delay 49 Caps Lock State 50 Numlock 50 USB Keyboard Speed 51 USB Keyboard Numeric Keypad 52 USB OEM Interface 53 USB OEM Device Usage 54 USB Interface Options 54 Transmit Labels i...

Page 5: ...mbologies 88 Code EAN UPC 89 Coupon Control 89 UPC A 90 UPC A Enable Disable 90 UPC A Check Character Transmission 90 Expand UPC A to EAN 13 91 UPC A Number System Character Transmission 91 UPC A 2D C...

Page 6: ...e Disable 118 Expand Code 128 to Code 39 118 Code 128 Check Character Transmission 118 Code 128 Function Character Transmission 119 Code 128 Quiet Zones 119 Code 128 Length Control 120 Code 128 Set Le...

Page 7: ...isable 151 Code 11 Check Character Calculation 151 Code 11 Check Character Transmission 152 Code 11 Length Control 152 Code 11 Set Length 1 153 GS1 DataBar Omnidirectional 155 GS1 DataBar Omnidirectio...

Page 8: ...ta Matrix Length Control 187 Data Matrix Set Length 1 187 Data Matrix Set Length 2 188 Maxicode 189 Maxicode Enable Disable 189 Maxicode Primary Message Transmission 189 Maxicode Length Control 190 Ma...

Page 9: ...rity Features 219 BT Security Mode 219 BT PIN Code 219 Select PIN Code Length 220 Set PIN Code 220 Other BT Features 221 BT Poll Rate 221 Power Off 221 Powerdown Timeout 222 References 223 RS 232 Para...

Page 10: ...cations 261 Error Codes 262 Base Station Indications Cordless Models ONLY 263 Base Station Button Indicators 263 Appendix B Standard Defaults 264 Appendix C Sample Barcodes 276 1D Barcodes 276 GS1 Dat...

Page 11: ...n system design data base design algorithms technology technical data or information implementation techniques and trade secrets related to the Software b any other trade secrets marked appropriately...

Page 12: ...third party licensors to any person other than End User s authorized employees or agents who are under confidentiality agreement and End User shall not use the Proprietary Information other than in c...

Page 13: ...ALINGS BETWEEN THE PARTIES WHETHER ORAL OR WRITTEN EXCEPT AS SET FORTH IN A FUTURE WRITING SIGNED BY BOTH PARTIES 8 Limitation Of Liability IN NO EVENT SHALL BALLUFF S LIABILITY FOR DAMAGES IF ANY WHE...

Page 14: ...nditions 11 4 It is agreed that a place of jurisdiction for legal actions falling within the jurisdiction as regards the subject matter of the Amtsgericht local courts shall be the Amtsgericht Stuttga...

Page 15: ...ppendix B Standard Defaults references common factory default settings for reader features and options Appendix C Appendix C Sample Barcodes offers sample barcodes for several common symbol ogies Appe...

Page 16: ...rm The family of BVS HS Q Series handheld area consists out of several models BVS HS QC SDR MA 01 01 Cable version with USB cable in a kit BVS HS QB SDR MA 02 02 Bluetooth version with basestation and...

Page 17: ...eated in the cradle it will sound a chirp to indicate that the cradle has detected the reader connection The LEDs on the base will indicate the status of the battery LED STATUS Power on Data Yellow On...

Page 18: ...ot expose the battery pack to liquids or allow the battery to get wet Do not apply voltages to the battery pack contacts WARNING In the event the battery pack leaks and the fluid gets into your eye do...

Page 19: ...European Directive 2006 66 EC 2011 65 EU 2002 96 EC and 2012 19 EU and subsequent modifica tions US and China regulatory and others laws and regulations about the environment 2 7 Replacing the Batter...

Page 20: ...ocess 1 Insert the top of the new pack inside the reader s handle 2 Rotate the battery pack downward while pressing the bottom side of the battery pack to seat securely into the contacts springs so th...

Page 21: ...Selection and set the desired interface 3 Configure Interface Settings only if not using factory settings for that interface 4 Go to Configuring Other Features if modifications are needed from factory...

Page 22: ...ure 4 USB Connection Connect the reader to a USB port on the terminal PC using the correct USB cable for the inter face type you ordered Reference Figure USB connection Figure 5 USB connection Other c...

Page 23: ...eeding Connect the interface cable before applying power to the Base Station 3 4 2 Base Station Connection and Routing 1 Remove the rubber Cable Stopper from the bottom of the Base Station 2 Securely...

Page 24: ...e plugged in reinsert the rubber Cable Stopper 4 Connect to an AC Adapter and plug the AC power cord into the wall outlet Figure 7 Connecting the Base Station Cable Stopper P C I F Cable Cable Stopper...

Page 25: ...th the cable facing downwards as shown in Figure Connecting to the Host to prevent undue strain on the socket 3 4 3 System and Network Layouts Stand Alone Layout 3 4 4 Connecting the Base when Securit...

Page 26: ...s after this tone indi cate a security error 3 4 6 Linking a BT Reader to a PC The reader can optionally be linked to a Bluetooth enabled PC with the serial port profile in either server mode or clien...

Page 27: ...n the programming barcode from this section which selects the appropriate interface type matching the system the reader will be connected to Next proceed to the corresponding section in this manual al...

Page 28: ...m Interfaces on page 37 Keyboard Settings on page 45 RS 232 FEATURES RS 232 standard interface Select RS232 STD Set RS 232 Interface Features starting on page 29 Select RS232 WN RS 232 Wincor Nixdorf...

Page 29: ...ettings allow you to enable disable symbologies set label lengths require check digit etc 3 6 4 Software Version Transmission The software version of the device can be transmitted over the RS 232 and...

Page 30: ...of this manual The programming items listed in the following sections show the factory default settings for each of the menu commands CAUTION Reading either of the Restore Factory Configuration comma...

Page 31: ...Reading Parameters on page 69 control various operating modes and indicators status functioning Symbology specific parameters 1D Symbologies on page 87 provides configuration of a personalized mix of...

Page 32: ...y or ignore host commands When set to ignore the reader will ignore all host commands except for those necessary for service mode flash programming mode keeping the interface active transmission of la...

Page 33: ...32 and USB interfaces are available in the next section RS 232 USB Com Inter faces on page 37 Reference Appendix B The most common configuration settings are listed in the Default column of the table...

Page 34: ...Reader Enter Exit Programming Mode 4 Configuration Using Barcodes Baud Rate See page 224 for information on this feature Baud Rate 1200 Baud Rate 2400 Baud Rate 4800 Baud Rate 9600 Baud Rate 19 200 Ba...

Page 35: ...e reader to interface with devices requiring a 7 bit or 8 bit ASCII protocol for sending and receiving data Stop Bits Set the number of stop bits to match host device requirements See page 224 for mor...

Page 36: ...pe accord ing to host device requirements See page 224 for more information Handshaking Control See page 224 for more information about this feature Parity None Parity Even Parity Odd DEFAULT CR2 CR2...

Page 37: ...rovided for feature descriptions and programming barcodes for each parameter A column has also been provided for recording of your preferred default settings for these same configurable features for a...

Page 38: ...to gain a user s attention to an illegal entry or other important event Intercharacter Delay No Delay Select Intercharacter Delay Setting To configure this feature scan the ENTER EXIT PROGRAMMING MODE...

Page 39: ...mmand ACK NAK Options This enables disables the ability of the reader to support the RS 232 ACK NAK protocol See page 226 for more information Beep On Not On File Disable Beep On Not On File Enable NF...

Page 40: ...s or any hex value from 0 to 0xFF can be selected See page 227 for more information Setting to previously defined characters such as XON XOFF or host commands conflicts with normal operation of these...

Page 41: ...for more information on setting this feature Select ACK NAK Timeout Value Setting To configure this feature scan the ENTER EXIT PROGRAMMING MODE barcode above then the barcode at left followed by the...

Page 42: ...he host Select ACK NAK Retry Count Setting To configure this feature scan the ENTER EXIT PROGRAMMING MODE barcode above then the barcode at left followed by the digits from the Alphanumeric characters...

Page 43: ...to disable the reader ASCII characters or any hex value from 0 to 0xFF can be selected See page 230 for more information on setting this feature Indicate Transmission Failure Disable Indication Indica...

Page 44: ...racters or any hex value from 0 to 0xFF can be selected See page 231 in References for more information on setting this feature Setting to previously defined characters such as XON XOFF or host com ma...

Page 45: ...ovided for feature descriptions and programming bar codes for each parameter A column has also been provided for recording of your preferred default settings for these same configurable features for a...

Page 46: ...ported Country Mode U S Country Mode Belgium Country Mode Britain Country Mode Croatia Supports only the interfaces listed in the Country Mode feature description Supports only the interfaces listed i...

Page 47: ...Mode French Canadian Country Mode Germany Supports only the interfaces listed in the Coun try Mode feature description Country Mode Hungary Country Mode Italy Supports only the interfaces listed in th...

Page 48: ...isted in the Coun try Mode feature description Country Mode Portugal Country Mode Romania Supports only the interfaces listed in the Country Mode feature description Supports only the interfaces liste...

Page 49: ...0x1F and characters from 0x80 to 0xFE are intended as an extended ASCII table see Microsoft Windows Codepage 1252 on page 293 Intercode Delay Specifies the delay between labels transmitted to the host...

Page 50: ...encoding keyboard is selected Numlock This option specifies the setting of the NUMLOCK key Make a mistake Scan the CANCEL barcode to abort and not save the entry string You can then start again at the...

Page 51: ...ng Barcodes USB Keyboard Speed This option specifies the USB poll rate for a USB keyboard This feature applies ONLY to the USB Keyboard interface USB Keyboard Speed 1ms USB Keyboard Speed 2ms USB Keyb...

Page 52: ...sing Barcodes USB Keyboard Numeric Keypad This option Controls whether numeric characters will be sent using standard keys or the numeric keypad USB Keyboard Speed 7ms USB Keyboard Speed 8ms USB Keybo...

Page 53: ...configure for the USB OEM interface Other USB interfaces are included in the appropriate chapter for their host type Reference The most common configuration settings are listed in the Default column o...

Page 54: ...ay need to change this setting to enable all devices to communicate Options are Table Top Reader Handheld Reader USB Interface Options This feature provides for an interface specific control mechanism...

Page 55: ...re IBM Standard Format Send labels in standard IBM format Mixed IBM Standard and Code 39 Format Code 39 Format Translate the following symbologies to Code 39 USB OEM Code128 Code 93 and Codabar Interf...

Page 56: ...page 233 for more detailed instructions on setting these features Global Prefix Suffix on page 57 Global AIM ID on page 58 Label ID on page 60 Label ID Pre Loaded Sets on page 61 Individually Set Labe...

Page 57: ...EXIT PROGRAMMING MODE barcode above to place the unit in Programming Mode then the Set Global Prefix or Set Global Suffix barcode fol lowed by the digits in hex from the Alphanumeric characters in Ap...

Page 58: ...lowed by A code character see some samples in the table below followed by A modifier character the modifier character is symbol dependent AIM IDs This feature enables disables addition of AIM IDs for...

Page 59: ...E 45 EAN13 P5 E 45 EAN13 COMPOSITE E 45 EAN8 E 45 EAN8 P2 E 45 EAN8 P5 E 45 EAN8 COMPOSITE E 45 FOLLET 2OF5 X 58 I2OF5 I 49 IATA INDUSTRIAL 2OF5 X 58 INDUSTRIAL 2OF5 X 58 ISBN X 58 ISBT128 CONCAT X 58...

Page 60: ...or following the transmitted barcode data depending upon how this option is enabled This feature provides options for configuring custom Label IDs or individually per symbology see Individually Set La...

Page 61: ...llowed by up to 3 characters from the ASCII Chart at the back of this manual See Label ID Set Individually Per Symbology on page 238 for detailed instructions on setting this feature Label ID Control...

Page 62: ...exit Programming Mode Set ABC Codabar Label ID Character s Set Code 32 Pharmacode Label ID Charac ter s Set Anker Plessey Label ID Character s Set Code 93 Label ID Character s Set Australian Postal C...

Page 63: ...et GS1 128 Label ID Character s Set EAN 8 P2 Label ID Character s Set GS1 128 Composite Label ID Character s Set EAN 8 P5 Label ID Character s Set GSI DataBar Limited Label ID Character s Set Follett...

Page 64: ...er s Set MSI Label ID Character s Set Industrial 2 of 5 Label ID Character s Set Planet Postal Code Label ID Character s Set Interleaved 2 of 5 Label ID Character s Set Plessey Label ID Character s Se...

Page 65: ...s Set Royal Postal Code Label ID Character s Set UPC A P2 Label ID Character s Set Standard 2 of 5 Label ID Character s Set UPC A P5 Label ID Character s Set Swedish Postal Code Label ID Character s...

Page 66: ...D Symbologies Set Aztec Label ID Character s Set Maxicode Label ID Character s Set China Sensible Label ID Character s Set PDF 417 Label ID Character s Set Data Matrix Label ID Character s Set Micro P...

Page 67: ...ripts Please contact our TecSupport for further information Case Conversion This feature allows conversion of the case of all alphabetic characters to upper or lower case Case conversion affects ONLY...

Page 68: ...ASCII values The first character in the pair is the character that will be converted The second character in the pair is the character to convert to If the character to convert in a pair is FF then no...

Page 69: ...Features on page 76 Scan Mode on page 76 Stand Mode Indication on page 77 Stand Operation on page 77 Pick Mode on page 78 Stand Mode Sensitivity on page 78 Stand Mode Illumination Off Time on page 79...

Page 70: ...he unit reads a label and sees the same label again within the specified timeout the second read is ignored Double Read Timeout does not apply to scan modes that require a trigger pull for each label...

Page 71: ...to Indicate This feature specifies when the reader will provide indication beep and or flash its green LED upon successfully reading a barcode Double Read Timeout 0 9 Second Double Read Timeout 1 Seco...

Page 72: ...mono or bitonal beep sound Good Read Beep Frequency Adjusts the good read beep to sound at a selectable low medium or high frequency selectable from the list below Controls the beeper s pitch tone Go...

Page 73: ...ep Length Good Read Beep Length 60 msec Good Read Beep Length 80 msec Good Read Beep Length 100 msec Good Read Beep Length 120 msec Good Read Beep Length 140 msec Good Read Beep Length 160 msec Good R...

Page 74: ...Configuration Using Barcodes Good Read Beep Volume Selects the beeper volume loudness upon a good read beep There are three selectable volume levels Good Read Beep Volume Beeper Off Good Read Beep Vol...

Page 75: ...for setting this feature Good Read LED Duration Setting Keep LED on until next trigger pull Select Good Read LED Duration Setting To configure this feature scan the ENTER EXIT PROGRAMMING MODE barcode...

Page 76: ...cts the reader s scan operating mode See page 243 in References for descriptions Scan Mode Trigger Single Scan Mode Trigger Hold Multiple Scan Mode Trigger Pulse Multiple Scan Mode Flashing Scan Mode...

Page 77: ...to switch to Stand Mode or when inserted into the special Stand support which automatically enables the Stand Mode 2 The reader is placed into the cradle of the base station cordless models only Belo...

Page 78: ...the reader to accurately target labels when they are placed close together such as on a pick sheet Stand Mode Sensitivity Sets the sensitivity level for stand mode wakeup Choices are low medium and hi...

Page 79: ...ce the state is entered The range for this setting is from 1 to 255 seconds in 1 second increments See page 245 in References for further description of this feature Select Stand Mode Time Setting To...

Page 80: ...ing this feature Stand Illumination Control OFF Stand Illumination Control ON Stand Illumination Control Dim Select Flash ON Time Setting To configure this feature scan the ENTER EXIT PROGRAMMING MODE...

Page 81: ...r all symbologies Select Flash OFF Time Setting To configure this feature scan the ENTER EXIT PROGRAMMING MODE barcode above then the barcode at left followed by the digits from the Alphanumeric chara...

Page 82: ...ion of this feature Aiming Off After Decoding Set Aiming Duration Timer To configure scan the ENTER EXIT PRO GRAMMING MODE barcode above then the barcode at left followed by the digits from the Alphan...

Page 83: ...beam after a good read Mobile Phone Mode This mode is useful for reading barcodes displayed on a mobile phone Green Spot Duration Disable Green Spot is Off Green Spot Duration Short 300 msec Green Sp...

Page 84: ...n the Disable barcode below to return the reader to its default for this feature To set decoding for only 2D codes go to 2D Normal Inverse Symbol Control on page 179 Partial Label Reading Control Disa...

Page 85: ...ntered is decoded and sent When Multiple Reading Mode is enabled the reader keeps on processing the image until all the labels present are decoded The reader then sorts the data from all the barcodes...

Page 86: ...ode length when Multiple Labels per Frame is enabled Select Symbologies for Multiple Labels Ordering To configure this feature scan the ENTER EXIT PROGRAMMING MODE barcode above then the barcode at le...

Page 87: ...s 2 Scan the correct barcode to set the desired programming feature or parameter You may need to cover unused barcodes on the page and possibly the facing page to ensure that the reader reads only the...

Page 88: ...an the ENTER EXIT PROGRAMMING Mode barcode 2 Scan the Disable All Symbologies barcode 3 Complete the programming sequence by reading the ENTER EXIT PROGRAMMING barcode Additional information about man...

Page 89: ...ng Barcodes Code EAN UPC Coupon Control This feature is used to control the reader s method of processing coupon labels Coupon Control Allow all coupon barcodes to be decoded Coupon Control Enable onl...

Page 90: ...logy UPC A Enable Disable When disabled the reader will not read UPC A barcodes UPC A Check Character Transmission Enable this option to transmit the check character along with UPC A barcode data UPC...

Page 91: ...cting this feature also changes the symbol ogy ID to match those required for EAN 13 UPC A Number System Character Transmission This feature enables disables transmission of the UPC A number system ch...

Page 92: ...el component be decoded when a base label of this symbology is decoded UPC E The following options apply to the UPC E symbology UPC E Enable Disable When disabled the reader will not read UPC E barcod...

Page 93: ...g with UPC E barcode data UPC E 2D Component This feature enables disables a requirement that a 2D label component be decoded when a base label for this symbology is decoded UPC E Check Character Tran...

Page 94: ...E data to the EAN 13 data format Selecting this feature also changes the symbol ogy ID to match those required for EAN 13 Expand UPC E to UPC A Expands UPC E data to the UPC A data format UPC E to EAN...

Page 95: ...This feature enables disables the ability to convert UPC E UPC A EAN 8 and EAN 13 labels into the GTIN 14 character format UPC E Number System Character Do not transmit UPC E Number System Character T...

Page 96: ...ogy EAN 13 Enable Disable When disabled the reader will not read EAN 13 JAN 13 barcodes EAN 13 Check Character Transmission Enable this option to transmit the check character along with EAN 13 barcode...

Page 97: ...N13 Flag1 character The Flag 1 character is the first character of the label EAN 13 ISBN Conversion This option enables disables conversion of EAN 13 JAN 13 Bookland labels starting with 978 to ISBN l...

Page 98: ...decoded when a base label of this symbology is decoded ISSN The following options apply to the ISSN symbology ISSN Enable Disable Enables disables conversion of EAN JAN13 Bookland labels starting with...

Page 99: ...an 8 symbology EAN 8 Enable Disable When disabled the reader will not read EAN 8 JAN 8 barcodes EAN 8 Check Character Transmission Enable this option to transmit the check character along with EAN 8 b...

Page 100: ...to EAN 13 JAN 13 EAN 8 2D Component This feature enables disables a requirement that a 2D label component be decoded when a base label for this symbology is decoded Expand EAN 8 to EAN 13 Disable Expa...

Page 101: ...affects all of these unless otherwise marked for each feature description UPC EAN Price Weight Check This feature enables disables calculation and verification of price weight check digits Price Weigh...

Page 102: ...cifies the number of quiet zones for UPC EAN labels Quiet zones are blank areas at the ends of a barcode typically 10 times the width of the narrowest bar or space in the label The property applies to...

Page 103: ...n are both decoded the reader will transmit the base label and add on If a UPC EAN base label is decoded with out an add on the base label will be transmitted without an add on Condi tional add on set...

Page 104: ...his option sets the time the reader will look for an add on when an add on fragment has been seen and optional add ons are enabled Also see Optional GS1 128 Add On Timer on page 106 Optional Add on Ti...

Page 105: ...Reader Enter Exit Programming Mode 4 Configuration Using Barcodes Optional Add on Timer 60ms Optional Add on Timer 70ms Optional Add on Timer 100ms Optional Add on Timer 120ms Optional Add on Timer 14...

Page 106: ...t after reading the linear EAN UPC part For UPC EAN add ons other than those of that type see Optional Add On Timer on page 104 Optional GS1 128 Add On Timer Disable Optional GS1 128 Add On Timer 10ms...

Page 107: ...onfiguration Using Barcodes Optional GS1 128 Add On Timer 60ms Optional GS1 128 Add On Timer 70ms Optional GS1 128 Add On Timer 100ms Optional GS1 128 Add On Timer 120ms Optional GS1 128 Add On Timer...

Page 108: ...nal GS1 128 Add On Timer 180ms Optional GS1 128 Add On Timer 200ms Optional GS1 128 Add On Timer 220ms Optional GS1 128 Add On Timer 240ms Optional GS1 128 Add On Timer 260ms Optional GS1 128 Add On T...

Page 109: ...optional Code 39 check character When disabled any check character in the label is treated as a data character Code 39 Disable Code 39 Enable Code 39 Check Character Calculation Don t Calculate Code...

Page 110: ...e disable transmission of Code 39 start and stop characters Code 39 Full ASCII Enables disables the translation of Code 39 characters to Code 39 full ASCII characters Code 39 Check Character Transmiss...

Page 111: ...r space in the label Code 39 Length Control This feature specifies either variable length decoding or fixed length decoding for the Code 39 symbology Variable Length For variable length decoding a min...

Page 112: ...50 characters Table Code 39 Length 1 Setting Examples provides examples for setting Length 1 See page 232 for detailed instructions on setting this feature Code 39 Length 1 Setting Examples STEP ACTIO...

Page 113: ...ot include start stop characters Table Code 39 Length 2 Setting Examples provides examples for setting Length 2 See page 232 for detailed instructions on setting this feature Code 39 Length 2 Setting...

Page 114: ...y to the Code 32 Italian Pharmaceutical Code symbology Code 32 Enable Disable When disabled the reader will not read Code 32 barcodes Code 32 Feature Setting Exceptions Trioptic Code Disable Trioptic...

Page 115: ...r along with Code 32 barcode data Code 32 Start Stop Character Transmission This option enables disables transmission of Code 32 start and stop characters Code 32 Check Character Transmission Don t Se...

Page 116: ...39 CIP Enable Disable Enables Disables ability of the reader to decode Code 39 CIP labels Code 39 Danish PPT The following options apply to the Code 39 Danish PPT symbology Code 39 Danish PPT Enable...

Page 117: ...39 LaPoste Enable Disable Enables disables the ability of the reader to decode Code39 La Poste labels Code 39 PZN The following options apply to the Code 39 PZN symbology Code 39 PZN Enable Disable E...

Page 118: ...ode 39 This feature enables disables expansion of Code 128 labels to Code 39 labels Code 128 Check Character Transmission Enable this option to transmit the check character along with Code 128 barcode...

Page 119: ...uiet Zones This feature specifies the number of quiet zones for Code 128 labels Quiet zones are blank areas at the ends of a barcode and are typically 10 times the width of the narrowest bar or space...

Page 120: ...ation Using Barcodes Code 128 Length Control This feature specifies either variable length decoding or fixed length decoding for the Code 128 symbology See page 231 for more information Code 128 Lengt...

Page 121: ...80 characters Table Code 128 Length 1 Setting Examples provides some examples for setting Length 1 See page 232 for detailed instructions on setting this feature Code 128 Length 1 Setting Examples STE...

Page 122: ...s to ignore this length only one fixed length Table Code 128 Length 2 Setting Examples provides examples for setting Length 2 See page 232 for detailed instructions on setting this feature Code 128 Le...

Page 123: ...GS1 128 data format Options are Transmit GS1 128 labels in Code 128 data format Transmit GS1 128 labels in GS1 128 data format Do not transmit GS1 128 labels GS1 128 2D Component This feature enables...

Page 124: ...option to enable disable ISBT128 concatenation of 2 labels ISBT 128 Force Concatenation When enabled this feature forces concatenation for ISBT ISBN 128 Concatenation Disable ISBN 128 Concatenation En...

Page 125: ...ation Using Barcodes ISBT 128 Concatenation Mode Specifies the concatenation mode between Static and Dynamic This option is only valid when ISBT 128 Concatenation is enabled see ISBT 128 Concatenation...

Page 126: ...128 Dynamic Concatenation Mode ISBT 128 Dynamic Concatenation Timeout 50 msec ISBT 128 Dynamic Concatenation Timeout 100 msec ISBT 128 Dynamic Concatenation Timeout 200 msec ISBT 128 Dynamic Concatena...

Page 127: ...xit Programming Mode 4 Configuration Using Barcodes Interleaved 2 of 5 I 2 of 5 The following options apply to the I 2 of 5 symbology I 2 of 5 Enable Disable When disabled the reader will not read I 2...

Page 128: ...2 of 5 Check Character Calculation Disable I 2 of 5 Check Character Calculation Check Standard Modulo 10 I 2 of 5 Check Character Calculation Check German Parcel I 2 of 5 Check Character Calculation...

Page 129: ...Length Control on page 129 Length 1 is the minimum label length if in Variable Length Mode or the first fixed length if in Fixed Length Mode The length includes the barcode s check and data characters...

Page 130: ...this appendix to enter numbers as you would select digits characters from a keypad 0 and 2 0 and 6 1 and 4 5 AND 0 6 Scan ENTER EXIT PROGRAMMING MODE Select I 2 of 5 Length 1 Setting Make a mistake S...

Page 131: ...s length only one fixed length Table I 2 of 5 Length 2 Setting Examples provides examples for setting Length 2 See page 232 for detailed instructions on setting this feature I 2 of 5 Length 2 Setting...

Page 132: ...P HR Enable Disable Enables Disables ability of reader to decode Interleaved 2 of 5 CIP HR labels Follett 2 of 5 The following options apply to the Follett 2 of 5 symbology Follett 2 of 5 Enable Disab...

Page 133: ...Disable When disabled the reader will not read Standard 2 of 5 barcodes Standard 2 of 5 Check Character Calculation This option enables disables calculation and verification of an optional Standard 2...

Page 134: ...either variable length decoding or fixed length decoding for the Standard 2 of 5 symbology Variable Length For variable length decoding a minimum and maximum length may be set Fixed Length For fixed l...

Page 135: ...charac ters Table Standard 2 of 5 Length 1 Setting Examples provides some examples for setting Length 1 See page 232 if you want detailed instructions on setting this feature Standard 2 of 5 Length 1...

Page 136: ...length only one fixed length Table Standard 2 of 5 Length 2 Setting Examples provides examples for setting Length 2 See page 232 for detailed instructions on setting this feature Standard 2 of 5 Lengt...

Page 137: ...Disable Enables Disables ability of reader to decode Industrial 2 of 5 labels Industrial 2 of 5 Check Character Calculation Enables Disables calculation and verification of an optional Industrial 2 o...

Page 138: ...r variable length decoding or fixed length decoding for the Industrial 2 of 5 symbology Variable Length For variable length decoding a minimum and maximum length may be set Fixed Length For fixed leng...

Page 139: ...cters Table Industrial 2 of 5 Length 1 Setting Examples provides some examples for setting Length 1 See page 232 if you want detailed instructions on setting this feature Industrial 2 of 5 Length 1 Se...

Page 140: ...ers A setting of 0 specifies to ignore this length only one fixed length Table Industrial 2 of 5 Length 2 Setting Examples provides examples for setting Length 2 See page 232 for detailed instructions...

Page 141: ...ogy IATA Enable Disable Enables Disables the ability of the reader to decode IATA labels IATA Check Character Transmission Enables Disables calculation and verification of an optional Industrial 2 of...

Page 142: ...haracter Calculation Enable this option to enables disables calculation and verification of an optional Codabar check character When disabled any check character in the label is treated as a data char...

Page 143: ...along with Codabar barcode data Codabar Start Stop Character Transmission Enable this option to enable disable transmission of Codabar start and stop characters Codabar Check Character Transmission D...

Page 144: ...characters Codabar Start Stop Character Match When enabled this option requires that start and stop characters match Codabar Check Character Set ABCD TN E Codabar Check Character Set ABCD ABCD Codabar...

Page 145: ...pace in the label Codabar Length Control This feature specifies either variable length decoding or fixed length decoding for the Codabar symbology Variable Length For variable length decoding a minimu...

Page 146: ...cter The length can be set from 3 to 50 characters Table Codabar Length 1 Setting Examples provides some examples for setting Length 1 See page 232 for detailed instructions on setting this feature Co...

Page 147: ...from 3 to 50 characters A setting of 0 specifies to ignore this length only one fixed length Table Codabar Length 2 Setting Examples provides examples for setting Length 2 See page 232 for detailed i...

Page 148: ...C Codabar symbology ABC Codabar Enable Disable Enables Disables ability of reader to decode ABC Codabar labels ABC Codabar Concatenation Mode Specifies the concatenation mode between Static and Dynami...

Page 149: ...second ticks used by the ABC Codabar Dynamic Concatenation Mode ABC Codabar Dynamic Concatenation Time out 50 msec ABC Codabar Dynamic Concatenation Timeout 100 msec ABC Codabar Dynamic Concatenation...

Page 150: ...ader Enter Exit Programming Mode 4 Configuration Using Barcodes ABC Codabar Force Concatenation Forces labels starting or ending with D to be concatenated ABC Codabar Force Concatenation Disable ABC C...

Page 151: ...ot read Code 11 barcodes Code 11 Check Character Calculation This option enables disables calculation and verification of optional Code 11 check character Code 11 Disable Code 11 Enable Code 11 Check...

Page 152: ...ecifies either variable length decoding or fixed length decoding for the Code 11 symbology Variable Length For variable length decoding a minimum and maximum length may be set Fixed Length For fixed l...

Page 153: ...harac ters Table Code 11 Length 1 Setting Examples provides some examples for setting Length 1 See page 232 for detailed instructions on setting this feature Code 11 Length 1 Setting Examples STEP ACT...

Page 154: ...re this length only one fixed length Table Code 11 Length 2 Setting Examples provides examples for setting Length 2 See page 232 for detailed instructions on setting this feature Code 11 Length 2 Sett...

Page 155: ...nable Disable When disabled the reader will not read GS1 DataBar Omnidirectional barcodes GS1 DataBar Omnidirectional GS1 128 Emulation When enabled GS1 DataBar Omnidirectional barcodes will be transl...

Page 156: ...directional 2D Component This feature enables disables a requirement that a 2D label component be decoded when a base label for this symbology is decoded GS1 DataBar Omnidirectional 2D Compo nent Disa...

Page 157: ...DataBar Expanded Enable Disable When disabled the reader will not read GS1 DataBar Expanded barcodes GS1 DataBar Expanded GS1 128 Emulation When enabled GS1 DataBar Expanded barcodes will be translate...

Page 158: ...tion Using Barcodes GS1 DataBar Expanded 2D Component This feature enables disables a requirement that a 2D label component be decoded when a base label of this symbology is decoded GS1 DataBar Expand...

Page 159: ...pecifies either variable length decoding or fixed length decoding for the GS1 DataBar Expanded symbology Variable Length For variable length decoding a minimum length may be set Fixed Length For fixed...

Page 160: ...Table GS1 DataBar Expanded Length 1 Setting Examples provides some examples for setting Length 1 See page 232 for detailed instructions on setting this feature GS1 DataBar Expanded Length 1 Setting E...

Page 161: ...nore this length only one fixed length Table GS1 DataBar Expanded Length 2 Setting Examples provides examples for setting Length 2 See page 232 for detailed instructions on setting this feature GS1 Da...

Page 162: ...r Limited Enable Disable When disabled the reader will not read GS1 DataBar Limited barcodes GS1 DataBar Limited GS1 128 Emulation When enabled GS1 DataBar Limited barcodes will be translated to the G...

Page 163: ...ponent be decoded when a base label of this symbology is decoded Code 93 The following options apply to the Code 93 symbology Code 93 Enable Disable Enables Disables ability of reader to decode Code 9...

Page 164: ...ter Transmission Enables disables transmission of an optional Code 93 check character Code 93 Check Character Calculation Disable Code 93 Check Character Calculation Enable Check C Code 93 Check Chara...

Page 165: ...This feature specifies either variable length decoding or fixed length decoding for the Code 93 symbology Variable Length For variable length decoding a minimum and maximum length may be set Fixed Len...

Page 166: ...acters Table Code 93 Length 1 Setting Examples provides some examples for setting Length 1 See page 232 for detailed instructions on setting this feature Code 93 Length 1 Setting Examples STEP ACTION...

Page 167: ...om 1 to 50 characters A setting of 0 specifies to ignore this length only one fixed length Table CODE 93 Length 2 Setting Examples provides examples for setting Length 2 See page 232 for detailed inst...

Page 168: ...Enables disables quiet zones for Code 93 MSI The following options apply to the MSI symbology MSI Enable Disable Enables Disables ability of reader to decode MSI labels Code 93 Quiet Zones Quiet Zone...

Page 169: ...haracter MSI Check Character Transmission Enables disables transmission of an MSI check character MSI Check Character Calculation Disable MSI Check Character Calculation Enable Mod10 MSI Check Charact...

Page 170: ...feature specifies either variable length decoding or fixed length decoding for the MSI symbol ogy Variable Length For variable length decoding a minimum and maximum length may be set Fixed Length For...

Page 171: ...om 01 to 50 characters Table MSI Length 1 Setting Examples provides some examples for setting Length 1 See page 232 for detailed instructions on setting this feature MSI Length 1 Setting Examples STEP...

Page 172: ...to 50 characters A setting of 0 specifies to ignore this length only one fixed length Table MSI Length 2 Setting Examples provides examples for setting Length 2 See page 232 for detailed instructions...

Page 173: ...ter Calculation Enables Disables calculation and verification of an optional Plessey check character Plessey Disable Plessey Enable Plessey Check Character Calculation Disable Plessey Check Character...

Page 174: ...es either variable length decoding or fixed length decoding for the Plessey symbology Variable Length For variable length decoding a minimum and maximum length may be set Fixed Length For fixed length...

Page 175: ...01 to 50 characters Table Plessey Length 1 Setting Examples provides some examples for setting Length 1 See page 232 for detailed instructions on setting this feature Plessey Length 1 Setting Examples...

Page 176: ...0 characters A setting of 0 specifies to ignore this length only one fixed length Table Plessey Length 2 Setting Examples provides examples for setting Length 2 See page 232 for detailed instructions...

Page 177: ...stem To set most features 1 Scan the ENTER EXIT PROGRAMMING barcode at the top of applicable programming pages 2 Scan the correct barcode to set the desired programming feature or parameter You may ne...

Page 178: ...software will spend attempting to decode a 2D label The selectable range is 10 milliseconds to 2 55 milliseconds 2D Maximum Decoding Time 100 msec 2D Maximum Decoding Time 200 msec 2D Maximum Decoding...

Page 179: ...e for decoding normal negative printed 2D symbols This configura tion item applies globally to all the 2D symbologies that support that feature according to Stan dard AIM Specification Data Matrix QR...

Page 180: ...ngth 1 is the minimum label length if in Variable Length Mode or the first fixed length if in Fixed Length Mode Characters can be set from 0001 to 3 832 characters in increments of 0001 pad with zeroe...

Page 181: ...and Held Barcode Reader Enter Exit Programming Mode 4 Configuration Using Barcodes Make a mistake Scan the CANCEL barcode to abort and not save the entry string You can then start again at the beginni...

Page 182: ...oes See page 232 for detailed instructions on setting this feature Select Aztec Code Length 2 Setting To configure this feature scan the ENTER EXIT PROGRAMMING MODE barcode above then the barcode at l...

Page 183: ...ode Length Control This feature specifies either variable length decoding or fixed length decoding for this symbology Variable Length For variable length decoding a minimum and maximum length may be s...

Page 184: ...See page 232 for detailed instructions on setting this feature Select China Sensible Code Length 1 Setting To configure this feature scan the ENTER EXIT PROGRAMMING MODE barcode above then the barcod...

Page 185: ...pad with zeroes See page 232 for detailed instructions on setting this feature Select China Sensible Code Length 2 Setting To configure this feature scan the ENTER EXIT PROGRAMMING MODE barcode above...

Page 186: ...x with different form factors Choices are Square Style Rectangular Style Both Square and Rectangular Style The configuration item can also be configured as a bit mask to filter one or more Data Matrix...

Page 187: ...h Mode Characters can be set from 0001 to 3 116 characters in increments of 0001 pad with zeroes See page 232 for detailed instructions on setting this feature Data Matrix Length Control Variable Leng...

Page 188: ...oes See page 232 for detailed instructions on setting this feature Select Data Matrix Length 2 Setting To configure this feature scan the ENTER EXIT PROGRAMMING MODE barcode above then the barcode at...

Page 189: ...ables disables ability of reader to decode Maxicode labels Maxicode Primary Message Transmission Enables disables the transmission of only the Primary Message when the Secondary Message is not readabl...

Page 190: ...Characters can be set from 0001 to 0145 characters in increments of 0001 pad with zeroes See page 232 for detailed instructions on setting this feature Maxicode Length Control Variable Length Maxicode...

Page 191: ...ith zeroes See page 232 for detailed instructions on setting this feature Select Maxicode Length 2 Setting To configure this feature scan the ENTER EXIT PROGRAMMING MODE barcode above then the barcode...

Page 192: ...th Control This feature specifies either variable length decoding or fixed length decoding for this symbology Variable Length For variable length decoding a minimum and maximum length may be set Fixed...

Page 193: ...value greater than 2 710 will be considered to be 2 710 See page 232 for detailed instructions on setting this feature Select PDF417 Length 1 Setting To configure this feature scan the ENTER EXIT PRO...

Page 194: ...with zeroes in increments of 01 Any value greater than 2 710 will be considered to be 2 710 See page 232 for detailed instructions on setting this feature Select PDF417 Length 2 Setting To configure t...

Page 195: ...7 Code 128 GS1 128 Emulation Specifies which AIM ID to use for MicroPDF labels when doing Code 128 or GS1 128 emulation Emulation choices are Micro PDF AIM ID and label type Code 128 EAN128 AIM Id and...

Page 196: ...can be set from 0001 to 0366 characters pad with zeroes in increments of 01 Any value greater than 0366 will be con sidered to be 0366 See page 232 for detailed instructions on setting this feature M...

Page 197: ...1 Any value greater than 0366 will be con sidered to be 0366 See page 232 for detailed instructions on setting this feature Select Micro PDF417 Length 2 Setting To configure this feature scan the ENTE...

Page 198: ...gth Control This feature specifies either variable length decoding or fixed length decoding for this symbology Variable Length For variable length decoding a minimum and maximum length may be set Fixe...

Page 199: ...es See page 232 for detailed instructions on setting this feature Select QR Code Length 1 Setting To configure this feature scan the ENTER EXIT PROGRAMMING MODE barcode above then the barcode at left...

Page 200: ...s See page 232 for detailed instructions on setting this feature Select QR Code Length 2 Setting To configure this feature scan the ENTER EXIT PROGRAMMING MODE barcode above then the barcode at left f...

Page 201: ...Code Length Control This feature specifies either variable length decoding or fixed length decoding for this symbology Variable Length For variable length decoding a minimum and maximum length may be...

Page 202: ...e page 232 for detailed instructions on setting this feature Select Micro QR Code Length 1 Setting To configure this feature scan the ENTER EXIT PROGRAMMING MODE barcode above then the barcode at left...

Page 203: ...pad with zeroes See page 232 for detailed instructions on setting this feature Select QR Code Length 2 Setting To configure this feature scan the ENTER EXIT PROGRAMMING MODE barcode above then the bar...

Page 204: ...des 4 9 11UCC Composite UCC Composite Enable Disable Enables disables the ability of the reader to decode the stacked part of a UCC Composite label This feature is not effective when Global AIM IDs ar...

Page 205: ...l wait for the stacked part of a UCC Composite label before transmitting the linear label without an add on UCC Optional Composite Timer Timer Disabled UCC Optional Composite Timer 100msec UCC Optiona...

Page 206: ...st Kix Portugal Post Postal Code Selection Disable All Postal Codes Postal Code Selection Enable Postnet Postal Code Selection Enable Planet Postal Code Selection Enable Royal Mail Postal Code Selecti...

Page 207: ...d Barcode Reader Enter Exit Programming Mode 4 Configuration Using Barcodes Postnet BB Control Controls the ability of the reader to decode B and B fields of Postnet labels Postnet BB Control Disable...

Page 208: ...sion Beep on page 209 Beep Frequency on page 209 Beep Duration on page 210 Beep Volume on page 211 Disconnect Beep on page 211 Docking Beep on page 212 Leash Alarm on page 212 Configuration Updates st...

Page 209: ...sables the Good Transmission Beep indication When enabled a beep occurs when a Label is correctly transmitted to the base Beep Frequency Adjusts radio specific beep indications to sound at a low mediu...

Page 210: ...ure controls the duration of radio specific beep indications Beep Duration 60 msec Beep Duration 80 msec Beep Duration 100 msec Beep Duration 120 msec Beep Duration 140 msec Beep Duration 160 msec Bee...

Page 211: ...ic beep indications There are three select able volume levels Disconnect Beep Enables disables the beep indication that a handheld has become connected or disconnected from a Base Station Beep Volume...

Page 212: ...nces where the reader might inadvertently have been placed in a bag or cart For this mode to be effective the reader must be linked to the Base Station If the reader is asleep or disconnected from the...

Page 213: ...ies Standard Hand Held Barcode Reader Enter Exit Programming Mode 4 Configuration Using Barcodes Leash Alarm 5 Seconds Leash Alarm 10 Seconds Leash Alarm 25 Seconds Leash Alarm 30 Seconds CBTLB05 CR C...

Page 214: ...method when the Auto Configuration Update feature is disabled and you want a one time config uration update to be performed on the reader Copy Configuration to Base Station Scan the following label to...

Page 215: ...the handheld goes out of range and is disconnected from the remote device Manual The handheld will always store labels to Flash memory The user must manually send the stored labels to the remote devic...

Page 216: ...delay in 10 msec increments between transmitting labels stored in batch memory Do not scan an ENTER EXIT PROGRAMMING MODE label in conjunction with this barcode RF Batch Mode Transmit Delay No Delay...

Page 217: ...data inclusion Source Radio Address Transmission Enables disables the ability of source radio address information to be transmitted to the host and if so at what position with respect to the label da...

Page 218: ...rcode at left followed by the digits from the Alphanumeric characters in Appendix 18 Use the barcodes in this appendix to enter numbers as you would select digits characters from a keypad rep resentin...

Page 219: ...d examples for this feature BT Security Mode This feature enables disables authentication and encryption of the BT link Use the feature BT PIN Code on page 219 to specify the length and digits in the...

Page 220: ...e Set 4 character BT PIN Code To configure this feature scan the ENTER EXIT PROGRAMMING MODE barcode above then the barcode at left followed by the digits from the Alphanumeric characters in Appendix...

Page 221: ...rcodes Other BT Features BT Poll Rate This feature specifies the time between BT polls Power Off See Power Off on page 27 for information about this BT feature BT Poll Rate Maximum BT Poll Rate BT Pol...

Page 222: ...re sets the time for automatically switching the unit off when the imager has been idle Powerdown Timeout Disable Powerdown Timeout 10 minutes Powerdown Timeout 20 minutes Powerdown Timeout 30 minutes...

Page 223: ...a Editing starting on page 233 Global Prefix Suffix on page 234 Global AIM ID on page 235 Label ID on page 236 Character Conversion on page 241 Reading Parameters starting on page 242 Good Read LED Du...

Page 224: ...er Select the parity type according to host device requirements Select None when no parity bit is required Select Odd parity and the parity bit value is set to 0 or 1 based on data to ensure that an o...

Page 225: ...odes in this appendix to enter numbers as you would select digits characters from a keypad that repre sent the duration which was determined in the steps above You will hear a two beep indica tion aft...

Page 226: ...MODE to enter Programming Mode 4 Scan the barcode SELECT ACK CHARACTER SETTING 5 Scan the appropriate two alphanumeric characters from the keypad in Appendix 18 Use the barcodes in this appendix to en...

Page 227: ...a key pad that represent the desired character value in step 1 above The second character will cause a two beep indication 6 Scan the ENTER EXIT PROGRAMMING MODE barcode to exit Programming Mode This...

Page 228: ...ppendix to enter numbers as you would select digits characters from a keypad that repre sent the duration which was determined in the steps above You will hear a two beep indica tion after the last ch...

Page 229: ...its characters from a keypad that repre sent the number which was determined in the steps above You will hear a two beep indica tion after the last character 6 Scan the ENTER EXIT PROGRAMMING MODE bar...

Page 230: ...from a key pad that represent the desired character value in step 1 above The second character will cause a two beep indication 6 Scan the ENTER EXIT PROGRAMMING MODE barcode to exit Programming Mode...

Page 231: ...ication 6 Scan the ENTER EXIT PROGRAMMING MODE barcode to exit Programming Mode This completes the procedure See Table Enable Character Setting Examples for some examples of how to set this feature En...

Page 232: ...riable Length For variable length decoding a minimum and maximum length may be set on page 231 Mode or the second fixed length if in Fixed Length For fixed length decoding two different lengths may be...

Page 233: ...le output for advanced users Factory default settings for data editing is typically set to NONE A prefix or suffix may be applied only to a specified symbology reference 1D Code Selection starting on...

Page 234: ...de back cover of this manual to find the hex value assigned to the desired character The corresponding hex number for the character is 24 To enter this selection code scan the 2 and 4 barcodes from Ap...

Page 235: ...haracter see the table below followed by A modifier character the modifier character is symbol dependent Figure 3 AIM ID This feature enables disables addition of AIM IDs for all symbology types SYMBO...

Page 236: ...changing from one Label ID set to another all other reader configuration settings including the host interface type will be erased and set to the stan dard factory defaults Any custom configuration o...

Page 237: ...2OF5 CIP HR e IATA INDUSTRIAL 2OF5 IA 494100 260000 INDUSTRIAL 2OF5 W 570000 W 570000 ISBN I 490000 400000 ISBT128 CONCAT f 660000 f 660000 ISSN n 6E0000 n 6E0000 MATRIX 2OF5 g MAXICODE MC 4D4300 x 78...

Page 238: ...iated hex characters as 3D Turn to Use the bar codes in this appendix to enter numbers as you would select digits characters from a keypad starting on page 281 and scan the barcodes representing the h...

Page 239: ...239 www balluff com BVS HS Q Series Standard Hand Held Barcode Reader 5 References Figure 4 Label ID Position Options OR Prefix Suffix Label ID Label ID Bar Code Data Aim ID...

Page 240: ...Bar Omnidirec tional Code 39 Interleaved 2 of 5 Code 32 4 Custom Label ID example desired characters D B C 3 P H 5 Find hex equivalents from the inside back cover then scan in these digits characters...

Page 241: ...ld look as follows after the character conversion BB22BB22 The A characters were converted to B characters and the 1 characters were converted to 2 char acters Nothing is done with the last two charac...

Page 242: ...ppendix 18 Use the barcodes in this appendix to enter numbers as you would select digits characters from a keypad representing the duration which was determined in the steps above You will hear a two...

Page 243: ...ous reading is activated until Reading Active Time on page 245 has elapsed or the trigger has been released and pulled again Double Read Timeout on page 70 prevents undesired multiple reads of the sam...

Page 244: ...om the keypad in Appendix 18 Use the barcodes in this appendix to enter numbers as you would select digits characters from a keypad that repre sent the setting which was determined in the steps above...

Page 245: ...s from a keypad that repre sent the duration which was determined in the steps above You will hear a two beep indica tion after the last character 6 Scan the ENTER EXIT PROGRAMMING MODE barcode to exi...

Page 246: ...a keypad that repre sent the duration which was determined in the steps above You will hear a two beep indica tion after the last character 6 Scan the ENTER EXIT PROGRAMMING MODE barcode to exit Progr...

Page 247: ...ou would select digits characters from a keypad representing the duration which was determined in the steps above You will hear a two beep indication after the last character 6 Scan the ENTER EXIT PRO...

Page 248: ...ct digits characters from a keypad that repre sent the duration which was determined in the steps above You will hear a two beep indica tion after the last character 6 Scan the ENTER EXIT PROGRAMMING...

Page 249: ...barcode SELECT SYMBOLOGIES FOR MULTIPLE LABELS ORDERING 5 Scan the appropriate two alphanumeric characters from the keypad in Appendix 18 Use the barcodes in this appendix to enter numbers as you woul...

Page 250: ...S1 DataBar_LIM_ID 0A EAN128 34 GS1 DataBar_LIM_COMP 0B C128_PROGRAMMING_LA BEL 35 GS1 DataBar_Omnidirectional_ COMP 0C CODE128 36 GS1 DataBar_EXP_COMP 0D FNC3_C128_LABEL 37 GENERIC_DATA 0E DATA MATRIX...

Page 251: ...ransferred and updated in a linked base station 1B EAN85 46 FOLLETT_2OF5 1C Reserved 47 Reserved 1D EAN132 48 Reserved 1E EAN135 49 CODE39_CIP 1F EAN138 4A ABC_CODABAR 20 ISBN_ID 4B I2OF5_CIP 21 TWO_L...

Page 252: ...ix to enter numbers as you would select digits characters from a keypad that repre sent the hexadecimal characters which were determined in the steps above You will hear a two beep indication after th...

Page 253: ...g the hexadecimal entries determined in the steps above You will hear a two beep indication after the last character 7 Scan the ENTER EXIT PROGRAMMING MODE barcode to exit Programming Mode Figure 5 BT...

Page 254: ...0mA N A Idle standby typical 50mA N A Battery Type N A Li Ion battery pack Typical charge time for full charge from full dis charge N A 6 hours with Host Power through the micro USB cable connection N...

Page 255: ...to 40cm EAN 7 5mil 0 15cm 13mil 0 5 35cm PDF 417 6 6mil 1 0 130cm 10mil 0 21cm 15mil 0 5 24cm Data Matrix 10mil 1 0 13 cm 15mil 0 18cm QR Code 10mil 0 5 13cm 15mil 0 18cm Minimum Element Width Standa...

Page 256: ...417 QR Code Aztec Data Matrix Inverse Data Matrix Data Matrix is configurable for the following parameters Normal or Inverted Square or Rectangular Style Data length 1 3600 characters Maxicode QR Code...

Page 257: ...re 40 to 70 C Humidity Operating 0 to 95 relative humidity non condensing Drop Specifications Reader withstands 18 drops from 1 5 meters 5 0 feet to concrete Ambient Light Immunity Up to 86 000 Lux Co...

Page 258: ...on your prod uct for actual details as they may vary from those depicted Radio Features CAUTION The BVS HS Q series Handheld Reader is not user serviceable Opening the case of the unit can cause inte...

Page 259: ...odel or Base Station Side provide standard pinout information for the interface cable Figure 1 Standard Cable Pinouts Handheld Figure 2 Standard Cable Pinouts Base Station The signal descriptions in T...

Page 260: ...nd Held Barcode Reader 6 Appendix A Technical Specifications Standard Cable Pinouts Handheld BVS HS QC model or Base Station Side Pin RS 232 OEM USB 1 RTS out 2 D 3 D 4 GND GND GND 5 RX 6 TX 7 VCC VCC...

Page 261: ...to Indicate on page 71 The reader will beep once at cur rent frequency volume mono bi tonal setting and duration upon a successful label scan ROM Failure There is an error in the reader s software pr...

Page 262: ...of Label A label has been rejected N A Reader sounds three times at lowest frequency current volume Label Pro gramming Mode Accep tance of Par tial Label In cases where multiple labels must be readed...

Page 263: ...00mSec Programming Mode Yellow LED blinks quickly Configuration alignment with the handheld is in progress Red LED blinks quickly Battery charging in progress Red LED on Battery charging complete Gree...

Page 264: ...ONLY Baud Rate on page 34 9600 34 Data Bits on page 35 8 Data Bits 35 Stop Bits on page 35 1 Stop Bit 35 Parity on page 36 None 36 Handshaking Control on page 36 RTS 36 RS 232 USB COM Intercharacter D...

Page 265: ...cate on page 71 After Decode 71 Good Read Beep Type on page 72 Mono 72 Good Read Beep Frequency on page 72 High 72 Good Read Beep Length on page 73 80 ms 73 Good Read Beep Volume on page 74 High 74 Go...

Page 266: ...e EAN UPC Coupon Control on page 89 Enable only UPCA coupon decoding 89 UPC A UPC A Enable Disable on page 90 Enable 90 UPC A Check Character Transmission on page 90 Send 90 Expand UPC A to EAN 13 on...

Page 267: ...able 100 EAN 8 2D Component on page 100 2D Component Not Required 100 UPC EAN Global Settings UPC EAN Price Weight Check on page 101 Disable 101 UPC EAN Quiet Zones on page 102 Two Modules 102 Add Ons...

Page 268: ...Special Codes Code 39 Danish PPT Enable Disable on page 116 Disable 116 Code 39 LaPoste Enable Disable on page 117 Disable 117 Code 39 PZN Enable Disable on page 117 Disable 117 Code 128 Code 128 Ena...

Page 269: ...page 129 Variable 129 I 2 of 5 Set Length 1 on page 129 6 129 I 2 of 5 Set Length 2 on page 131 50 131 Interleaved 2 of 5 CIP HR Interleaved 2 of 5 CIP HR Enable Disable on page 132 Disable 132 Folle...

Page 270: ...142 Don t Calculate 142 Codabar Check Character Transmission on page 143 Send 143 Codabar Start Stop Character Transmis sion on page 143 Transmit 143 Codabar Start Stop Character Set on page 144 abcd...

Page 271: ...page 156 2D component not required 156 GS1 DataBar Expanded GS1 DataBar Expanded Enable Dis able on page 157 Disable 157 GS1 DataBar Expanded GS1 128 Emulation on page 157 Disable 157 GS1 DataBar Expa...

Page 272: ...172 Plessey Plessey Enable Disable on page 173 Disable 173 Plessey Check Character Calculation on page 173 Enable Plessey std check char verifica tion 173 Plessey Check Character Transmission on page...

Page 273: ...age 190 Variable 190 Maxicode Set Length 1 on page 190 1 190 Maxicode Set Length 2 on page 191 0145 191 PDF417 Enable Disable on page 192 Enable 192 PDF417 Length Control on page 192 Variable 192 PDF4...

Page 274: ...ge 211 High 211 Disconnect Beep on page 211 Enable 211 Docking Beep on page 212 Enable 212 Leash Alarm on page 212 Disable 212 Automatic Configuration Update on page 214 Enable 214 Copy Configuration...

Page 275: ...aults BT Security Mode on page 219 Disable 219 Select PIN Code Length on page 220 4 character BT PIN Code 220 Set PIN Code on page 220 31323334 Default Pin Code is 1234 220 BT Poll Rate on page 221 20...

Page 276: ...Reader 8 Appendix C Sample Barcodes 8 Appendix C Sample Barcodes The sample barcodes in this appendix are typical representations for their symbology types 1D Barcodes UPC A EAN 13 978033029095 Code 3...

Page 277: ...277 www balluff com BVS HS Q Series Standard Hand Held Barcode Reader 8 Appendix C Sample Barcodes Codabar 13579 Code 93 Code 11 123456789...

Page 278: ...odes GS1 DataBar RSS GS1 DataBar variants must be enabled to read the barcodes below see GS1 DataBar Omnidirectional on page 155 GS1 DataBar Expanded Stacked 10293847560192837465019283746029478 450366...

Page 279: ...s Standard Hand Held Barcode Reader 8 Appendix C Sample Barcodes GS1 DataBar 14 GS1 DataBar Omnidirectional Truncated 55432198673467 GS1 DataBar Omnidirectional Stacked 90876523412674 GS1 DataBar Omni...

Page 280: ...tandard Hand Held Barcode Reader 8 Appendix C Sample Barcodes 2D Barcodes Aztec Datamatrix China Sensible Code MaxiCode PDF 417 ABCabc Micro PDF 417 QR Code Micro QR Code 123456 UCC Composite Test Mes...

Page 281: ...com BVS HS Q Series Standard Hand Held Barcode Reader 9 Appendix D Keypad 9 Appendix D Keypad Use the barcodes in this appendix to enter numbers as you would select digits characters from a keypad 0 1...

Page 282: ...282 BVS HS Q Series Standard Hand Held Barcode Reader 9 Appendix D Keypad A B C D E F...

Page 283: ...rom 00 to 0x1F are sent as control character Ctrl Capital Key special keys are located from 0x80 to 0xA1 Control Character 02 Special keys are located from 00 to 0x1F and characters from 0x80 to 0xFE...

Page 284: ...F 0x NULL C SOH C S A STX C S B ETX C S C EOT C S D ENQ C S E ACK C S F BEL C S G BS HT TAB LF C S J VT C S K FF C S L CR Enter SO C S N SI C S O 1x DLE C S P DC1 C S Q DC2 C S R DC3 C S S DC4 C S T N...

Page 285: ...en Control Character is 02 x0 x1 x2 x3 x4 x5 X6 x7 x8 x9 xA xB xC xD xE xF 0x Ar Ar Al Al Cl Cl Cr Cr BS Tab S Tab Enter Keyp d Enter Ins Pg Up 1x Pg Dwn Hom e F6 F1 F2 F3 F4 F5 ESC F7 F8 F9 F10 2x Sp...

Page 286: ...A 0 93 A 0 94 A 0 95 6x A 0 96 A 0 97 A 0 98 A 0 99 A 1 00 A 1 01 A 1 02 A 1 03 A 1 04 A 1 05 A 1 06 A 1 07 A 1 08 A 1 09 A 1 10 A 1 11 7x A 1 12 A 1 13 A 1 14 A 1 15 A 1 16 A 1 17 A 1 18 A 1 19 A 1...

Page 287: ...3 A 1 14 A 1 15 A 1 16 A 1 17 A 1 18 A 1 19 A 1 20 A 1 21 A 1 22 A 1 23 A 1 24 A 1 25 A 1 26 A 1 27 8x A 0 128 A 0 129 A 0 130 A 0 131 A 0 132 A 0 133 A 0 134 A 0 135 A 0 136 A 0 137 A 0 138 A 0 139 A...

Page 288: ...C S T NAK C S U SYN C S V ETB C S W CAN C S X EM C S Y SUB C S Z ESC Esc FS C S GS C RS C S US C S _ 2x Spac e 3x 0 1 2 3 4 5 6 7 8 9 4x A B C D E F G H I J K L M N O 5x P Q R S T U V W X Y Z _ 6x a...

Page 289: ...F C S J VT C S K FF C S L CR Enter SO C S N SI C S O 1x DLE C S P DC1 C S Q DC2 C S R DC3 C S S DC4 C S T NAK C S U SYN C S V ETB C S W CAN C S X EM C S Y SUB C S Z ESC Esc FS C S GS C RS C S US C S _...

Page 290: ...2 X0 x1 x2 x3 x4 x5 x6 x7 x8 x9 xA xB xC xD xE xF 0x Ar Ar Al Al Cl Cl Cr Cr BS Tab S Tab Enter Keyp d Enter Ins Pg Up 1x Pg Dwn Hom e F6 F1 F2 F3 F4 F5 ESC F7 F8 F9 F10 2x Spac e 3x 0 1 2 3 4 5 6 7 8...

Page 291: ...BS C S H HT TAB LF C S J VT C S K FF C S L CR Enter SO C S N SI C S O 1x DLE C S P DC1 C S Q DC2 C S R DC3 C S S DC4 C S T NAK C S U SYN C S V ETB C S W CAN C S X EM C S Y SUB C S Z ESC Esc FS C S GS...

Page 292: ...X0 x1 x2 x3 x4 x5 x6 x7 x8 x9 xA xB xC xD xE xF 0x Ar Ar Al Al Cl Cl Cr Cr BS Tab S Tab Enter Keyp d Enter Ins Pg Up 1x Pg Dwn Hom e F6 F1 F2 F3 F4 F5 ESC F7 F8 F9 F10 2x Spac e 3x 0 1 2 3 4 5 6 7 8 9...

Page 293: ...VS HS Q Series Standard Hand Held Barcode Reader 10 4 Microsoft Windows Codepage 1252 Windows 1252 is a character encoding of the Latin alphabet used by default in the legacy com ponents of Microsoft...

Page 294: ...0B 0C 0D 0E 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F SP 0 1 2 3 4 5 6 7 8 9 20 21 22 23 24 25 26 27 28 29 2A 2B 2C 2D 2E 2F 30 31 32 33 34 35 36 37 38 39 3A 3B 3C 3D 3E 3F A B C D E F G H I...

Page 295: ...295 www balluff com BVS HS Q Series Standard Hand Held Barcode Reader NOTES...

Page 296: ...aries USA Balluff Inc 8125 Holton Drive Florence Kentucky 41042 0937 Phone 859 727 2200 1 800 543 8390 applications balluff com www balluff com World Headquarters Germany Balluff GmbH Schurwaldstra e...

Reviews: