38
BVS HS-Q Series
Standard Hand Held Barcode Reader
Enter/Exit Programming Mode
4
Configuration Using Barcodes
Intercharacter
Delay
This parameter specifies the intercharacter delay between the end of one character and the
beginning of the next. The delay can be set within a range of zero (0) to 990 milliseconds in 10ms
increments. A setting of zero specifies no delay.
See page 225
for more information.
Beep On ASCII
BEL
When this parameter is enabled, the reader issues a beep when a <BEL> character is detected
on the RS-232 serial line. <BEL> is issued to gain a user's attention to an illegal entry or other
important event.
Intercharacter Delay = No Delay
Select Intercharacter Delay Setting
To configure this feature, scan the ENTER/
EXIT PROGRAMMING MODE barcode
above, then the barcode at left followed by
the digits from the Alphanumeric characters
in
Appendix D, Use the barcodes in this
appendix to enter numbers as you would
select digits/characters from a keypad.
rep-
resenting your desired character(s). End by
reading the ENTER/EXIT barcode again.
Make a mistake? Scan the CANCEL barcode
to abort and not save the entry string. You
can then start again at the beginning.
CANCEL
CR2IC00(CR)
$CR2IC
~
DEFAULT
00 = No Intercharacter Delay
Beep On ASCII BEL = Disable
Beep On ASCII BEL = Enable
BB00(CR
DEFAULT
BB01(CR