129
www.balluff.com
BVS HS-Q Series
Standard Hand Held Barcode Reader
Enter/Exit Programming Mode
4
Configuration Using Barcodes
I 2 of 5 Check Character Transmission
Enable this option to transmit the check character along with I 2 of 5 barcode data.
I2CT00(CR)
I 2 of 5 Check Character Transmission =
Don’t Send
CI2CT01(CR)
I 2 of 5 Check Character Transmission = Send
DEFAULT
I 2 of 5 Length Control
This feature specifies either variable length decoding or fixed length decoding for the I 2 of 5 sym-
bology.
Variable Length:
For variable length decoding, a minimum and maximum length may be set.
Fixed Length:
For fixed length decoding, two different lengths may be set.
DEFAULT
CI2LC00(CR)
I 2 of 5 Length Control = Variable Length
CI2LC01(CR)
I 2 of 5 Length Control = Fixed Length
I 2 of 5 Set Length 1
This feature specifies one of the barcode lengths for
I 2 of 5 Length Control on page 129
. Length
1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length
Mode. The length includes the barcode’s check and data characters. The length can be set from
2 to 50 characters in increments of two.
Table 2 of 5 Length 1 Setting Examples
provides some examples for setting Length 1. See
for detailed instructions on setting this feature.
2 of 5 Length 1
Setting
Examples
STEP
ACTION
EXAMPLES
1
Desired Setting
2 Characters
6 Characters
14 Characters
50 Characters
2
Pad with leading
zeroes to yield
two digits
02
06
14
50