193
www.balluff.com
BVS HS-Q Series
Standard Hand Held Barcode Reader
Enter/Exit Programming Mode
4
Configuration Using Barcodes
PDF417 Set Length 1
Specifies one of the barcode lengths for
PDF417 Length Control on page 192
. Length 1 is the
minimum label length if in
Variable Length
Mode, or the first fixed length if in Fixed Length Mode.
Length includes the barcode’s data characters only. Characters can be set from 0001 to 2,710
characters (pad with zeroes) in increments of 01. Any value greater than 2,710 will be considered
to be 2,710.
for detailed instructions on setting this feature.
$CP4L1
Select PDF417 Length 1 Setting
To configure this feature, scan the ENTER/
EXIT PROGRAMMING MODE barcode
above, then the barcode at left followed by
the digits from the Alphanumeric characters
in
Appendix 18, Use the barcodes in this
appendix to enter numbers as you would
select digits/characters from a keypad.
rep-
resenting your desired character(s). End by
reading the ENTER/EXIT barcode again.
Make a mistake? Scan the CANCEL barcode
to abort and not save the entry string. You
can then start again at the beginning.
~
CANCEL
DEFAULT
0001 = Length 1 is 1 Character