242
BVS HS-Q Series
Standard Hand Held Barcode Reader
5
References
5.4
Reading
Parameters
5.4.1 Good Read LED
Duration
This feature specifies the amount of time that the Good Read LED remains on following a good
read. The good read LED on time can be set within a range of 10 milliseconds to 2,550 millisec-
onds (0.001 to 2.55 seconds) in 100ms increments.
Follow these instructions to set this feature:
1
Determine the desired setting in milliseconds. A setting of 0 means that the good read LED
stays on until the next time the trigger is pulled.
2
Divide the desired setting by 10 (setting is in 100ms increments). Pad the result with leading
zeroes to yield three digits. For example: 0 = 000, 5 = 000, 20 = 020, etc.
3
and scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Pro-
gramming Mode.
4
Scan the barcode: SELECT GOOD READ LED DURATION SETTING.
5
Scan the appropriate three digits from the keypad in
Appendix 18, Use the barcodes in this
appendix to enter numbers as you would select digits/characters from a keypad.
representing
the duration which was determined in the steps above. You will hear a two-beep indication
after the last character.
If you make a mistake before the last character, scan the CANCEL barcode
to abort and not save the entry string. You can then start again at the begin-
ning.
6
Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming Mode.
This completes the procedure. See
Table Good Read LED Duration Setting Examples
examples of how to set this feature.
Good Read LED
Duration Setting
Examples
STEP ACTION
EXAMPLES
1
Desired Setting
Good Read
LED stays on
until next
trigger pull
(00)
20ms
150ms
2550ms (2.55
sec.)
2
Divide by 10 (and pad
with leading zeroes)
000
002
015
255
3
Scan ENTER/EXIT PROGRAMMING MODE
4
Scan SELECT GOOD READ LED DURATION SETTING
5
Scan Three
Characters From
‘0’, ‘0’ and
‘0’
‘0’, ‘0’ and
‘2’
‘0’, ‘1’ and
‘5’
‘2’, ‘5’ and ‘5’
6
Scan ENTER/EXIT PROGRAMMING MODE