247
www.balluff.com
BVS HS-Q Series
Standard Hand Held Barcode Reader
5
References
5.5.5 Flash On Time
This feature specifies the ON time for the indicator LED while in Flash Mode. The selectable range
is 100 to 9,900 milliseconds (0.1 to 9.9 seconds), in 100 millisecond increments.
Follow these instructions to set this feature.
1
Determine the desired setting in milliseconds.
2
Divide the desired setting by 100 (setting is in 100ms increments). Pad the result with leading
zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc.
3
Go to
and scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Pro-
gramming Mode.
4
Scan the barcode: SELECT FLASH ON TIME SETTING.
5
Scan the appropriate two digits from the keypad in
Appendix 18, Use the barcodes in this
appendix to enter numbers as you would select digits/characters from a keypad.
representing
the duration which was determined in the steps above. You will hear a two-beep indication
after the last character.
If you make a mistake before the last character, scan the CANCEL barcode
to abort and not save the entry string. You can then start again at the begin-
ning.
6
Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming Mode.
This completes the procedure. See
Table Flash On Time Setting Examples
for examples of how
to set this feature.
Flash On Time
Setting
Examples
STEP ACTION
EXAMPLES
1
Desired Setting
500ms
1,000ms
(1 sec.)
5200ms
(5.2 sec.)
9,900ms
(9.9 sec.)
2
Divide by 100 (and pad
with leading zeroes to
yield two digits)
05
10
52
99
3
Scan ENTER/EXIT PROGRAMMING MODE
4
Scan SELECT FLASH ON TIME SETTING
5
Scan Two Characters
From
the barcodes in this
appendix to enter
numbers as you would
select digits/characters
from a keypad.
‘0’ and ‘5’
‘1’ and ‘0’
‘5’ and ‘2’
‘9’ and ‘9’
6
Scan ENTER/EXIT PROGRAMMING MODE