Enter/Exit Programming Mode
4
Configuration Using Barcodes
Label ID: Pre-
Loaded Sets
The reader supports two pre-loaded sets of Label IDs. See
"Label ID: Pre-loaded Sets" on
for details on the USA set and EU set.
CAUTION
AE(CR)
Label ID Pre-loaded Set = USA Set
$Ae(CR)
Label ID Pre-loaded Set = EU Set
DEFAULT
When changing from one Label ID set to another, all other reader configura-
tion settings, including the host interface type, will be erased and set to the
standard factory defaults. Any custom configuration or custom defaults will
be lost.
Individually Set
Label ID
This feature configures a Label ID individually for a single symbology. To set, first define whether
you want it as a prefix or suffix by reading a label below. Then turn to
tion − 1D Symbologies" on page 62
to select the symbology you want to set, followed by up to 3
characters from the ASCII Chart at the back of this manual. See
"Label ID: Set Individually Per
for detailed instructions on setting this feature.
Label ID Control
This option controls whether a Label ID is disabled, or sent as a prefix or suffix for a given symbol-
ogy type.
DEFAULT
DCO00(CR)
Label ID Transmission = Disable
IDCO01(CR)
Label ID Transmission = Enable as Prefix
DCO02(CR)
Label ID Transmission = Enable as Suffix