background image

 

 

 

 

 

BVS SC-_1280Z00-07-000 

SMART

CAMERA

 IO

 

User's manual 

Summary of Contents for BVS SC Series

Page 1: ...BVS SC _1280Z00 07 000 SMARTCAMERA IO User s manual...

Page 2: ...www balluff com...

Page 3: ...4 1 Product variants 9 4 2 Scope of delivery 10 4 2 1 Assembly 11 4 3 Product specification 13 4 3 1 Image sensor 13 4 3 2 Mechanical data 13 4 3 3 Electrical data 13 4 3 4 Operating conditions 14 4...

Page 4: ...1280Z00 70 000 SMARTCAMERA IO 6 5 Network settings LAN interface 34 6 5 1 Locating the camera in the network 34 6 5 2 Network configuration via BVS Cockpit 35 6 6 Digital I O interface 35 7 APPENDIX 3...

Page 5: ...f camera without additional software Simple user supporting operation Support of Industry 4 0 through Integrated flexible displays of process statistics These characteristics make it possible to easil...

Page 6: ...Benutzerdefiniert Characters transmitted in ASCII code are set in apostrophes e g L NOTE A note indicates important information that helps you optimize us age of the products WARNING A warning indicat...

Page 7: ...ROM EMC Electromagnetic compatibility EtherNet IP Ethernet Industrial Protocol FCC Federal Communications Commission FE Function ground GND Ground I O port Digital input output port ID Identification...

Page 8: ...regulations of the Balluff Enduser Licensing Agreement You may use the software only in compliance with these provisions If they should not yet be available Balluff GmbH will gladly provide the cur r...

Page 9: ...ty and acci dent prevention regulations are observed When connecting the SMARTCAMERA to an external controller observe proper selection and polarity of the connection as well as the power supply see C...

Page 10: ...ration and secured against unauthorized use Only service technicians from Balluff GmbH may repair defective devices Intervention in the product by the operator is not permitted due to safety reasons T...

Page 11: ...ERA itself no external soft ware is required for the configuration and monitor display Using standardized web browsers such as Google Chrome Mozilla Firefox or Internet Explorer the user can easily co...

Page 12: ...ewed directly onto the camera housing thereby meeting the requirements in accordance with IP67 NOTE Only C mount lenses with a maximum diameter of 42 mm and a length of 40 mm can be used here For lens...

Page 13: ...for installation at the location of use Four threads each at the rear the left and the right This ensures secure and reliable mount ing The following drawings describe the exact position of all mounti...

Page 14: ...e maximum engagement length is 5 mm The maximum tightening torque is 2 Nm The lateral screw connections have an M5 thread The maximum engagement length is 5 mm The maximum tightening torque is 2 6 Nm...

Page 15: ...l Painted aluminum die cast box Degree of protection IP67 with connectors and protection tube 2 Weight approx 360 g Dimensions L W H without connector without lens 110 62 55 mm 2 The enclosure rating...

Page 16: ...00 6 3 EN 55011 Vibration shock for opera tion inside EN 60068 Part 2 6 27 Operation Internally Height up to 2000 m Relative humidity maximum 80 for temperatures up to 31 C decreasing linearly to 50 a...

Page 17: ...ed I O signals are available I O Light 2 I O signals and supply voltage output e g for an external lighting WARNING The SMARTCAMERA and accessories shall be supplied by limited energy in accordance to...

Page 18: ...ust be limited accordingly LAN 8 pin M12 socket X coded Pin Description Function 1 BI_DA Bidirectional data Pair A 2 BI_DA Bidirectional data Pair A 3 BI_DB Bidirectional data Pair B 4 BI_DB Bidirecti...

Page 19: ...ries shall be supplied by limited energy in accordance to UL 61010 1 Third Edition Sub Clauses 9 4 or LPS in accordance to UL 60950 1 or Class 2 in accordance to UL 1310 or UL 1585 NOTE These inputs o...

Page 20: ...s well as NPN logic The input stage always features PNP logic I O 0 I O 1 power plug connectors Operation as input Voltage Signal 0 0 5 V 2 mA Signal 1 11 30 V 2 5 mA Delay 160 s Operation as output V...

Page 21: ...Every output may be loaded with a maximum current of 100 mA The maximum current for Common In and Common Out is 630 mA each For a description of the interconnections see the section I O Input connect...

Page 22: ...predominantly used in Europe The output is sourcing so that the load between I O and GND must be switched accordingly The load is connected with supply voltage if 1 is being output Figure 4 PNP output...

Page 23: ...age drop VD 2 V Delay 0 1 10 s 1 0 10 s Supply voltage output Voltage VP 24 V VDC VD 1 2 A max Voltage dropVD 2 V Among other things this makes it possible to easily connect lighting equipment to the...

Page 24: ...Signal 1 11 30 V I O zu VCommon In 2 8 mA Delay 0 1 70 s 1 0 150 s Operation as output PNP NPN Voltage Signal 0 High resistance High resistance 100 mA max Signal 1 24 V VCommon Out VD 0 V VCommon Out...

Page 25: ...In or is not connected Figure 7 PNP mode I O 0 configured as input If I O 0 is configured as output the output is connected with Common Out and the actua tor PLC input or similar is supplied with it i...

Page 26: ...n In with 24 V 19 2 30 VDC If I O 0 is configured as input it can be connected directly with the NPN output of a sen sor a PLC or similar A 1 signal is being detected if the input is connected with Co...

Page 27: ...overloaded e g by a short circuit it is switched off and periodically checked whether the fault occur rence is still present If the error was removed the output is again in normal operating state with...

Page 28: ...in configuration mode Red on Fault Red flashing Firmware update active Signal LED Off Signal 0 Yellow on Signal 1 The signal LED indicates the status of the I O cable null LAN LED Indicator Function L...

Page 29: ...possible Structure Consequences SMARTCAMERA and PC are connected directly via a LAN cable IP addresses are set automatically SMARTCAMERA and PC are in the same subnet of a local net work and a DHCP s...

Page 30: ...TE JavaScript must be enabled in the web browser 1 Record the serial number of the SMARTCAMERA The serial number is located on the nameplate on the SMARTCAMERA If the nameplate is not visible you can...

Page 31: ...5 FIRST STEPS 29 www matrix vision com BVS SC _1280Z00 70 000 SMARTCAMERA IO www balluff com Figure 14 Display of all SMARTCAMERAs in the network...

Page 32: ...2 Unzip the downloaded file It contains a A PDF document that describes the new functions fixed errors and the up date procedure b The file BVS_Cockpit_X X X sh This contains the new software and must...

Page 33: ...cess This may take up to 5 minutes The Power LED on the front side will flash red during the update The SMARTCAMERA is inaccessible in the network during the update ATTENTION Never disconnect the came...

Page 34: ...res that the supply voltage is provided via the power connection in any case The IO1 topology shows a simply design with an operating panel for the configuration of the SMARTCAMERA The interaction wit...

Page 35: ...nu is located in the upper section of the user interface It consists of the following menu items Menu item Meaning User login Camera selection System setting Help system 6 4 Selecting the communicatio...

Page 36: ...ers in different networks and to structure it in this way Since the different subnets on the other hand are con nected via switches the communication with the SMARTCAMERA is still possible In most net...

Page 37: ...en tered here This entry is optional if the same subnet is used exclusively to access the camera Port Which port the Web interface of the SMARTCAMERA can be accessed on Default is Port 80 Use Avahi B...

Page 38: ...ines the delay of the trigger or an output in milliseconds The default value of 0 means that the trigger will start without delay or rather will the output toggle when the tool Set outputs is running...

Page 39: ...6 I O 7 Power Pin 2 Pin 4 I O Pin 1 Pin 3 Pin 4 Pin 5 Pin 6 Pin 8 I O Light Pin 2 Pin 4 Figure 18 Control plan If I O 0 is operated as output pin 1 at the I O connection and pin 2 at the power connec...

Page 40: ...r PC retrieves it s IP address automatically DHCP 1 Open the settings of your network adapter and there the settings of the inter net protocoll TCP version 4 2 Set the IP address to automatically 3 In...

Page 41: ...ss Life sec SC NNNNNNNNNDE 20 UNIQUE 169 254 4 9 540 SC NNNNNNNNNDE 00 UNIQUE 169 254 4 9 549 You can also reach the camera with the IP address directly in this sample 169 254 4 9 Connection to the ca...

Page 42: ...allow a guest access to the shared fold ers BVS Cockpit releases 2 3 0 and 2 2 2 some times also with error code 0x80070035 Update BVS Cockpit to a version 2 3 0 which allows accessing the shared fol...

Page 43: ...not included in the scope of delivery Protection tube BAM02NA BAM PC VS 023 1 Protection tube for lenses up to a length of 40 mm BAM02W0 BAM PC VS 023 1 01 Protection tube for lenses up to a length o...

Page 44: ...002 0 5 40 31 A C Mount spacer rings 0 5 1 5 10 20 40 mm Touchpanel PC BAE00WC BAE PD VS 011 01 Touchpanel PC 12 Mounting accessories BAM00ZW BAM MB MS 038 B19 1 Mounting bracket SMARTCAMERA BAM01YT B...

Page 45: ...Balluff GmbH Schurwaldstra e 9 73765 Neuhausen a d F Germany Tel 49 7158 173 0 Fax 49 7158 5010 balluff balluff de www balluff com www balluff com...