16
english
5
Configuration and parameterization (continued)
5.3
Parameterization using the
Config-Assembly
When starting, the PLC transmits the
Config-Assembly
to
the BTL7-V50D-…. The settings are applied if the
Config_
assembly_parameter_recognition
flag is set. Any deviating
settings via the
Position Sensor Object
or the device
configuration object are ignored.
A practical example of parameterization using the
Config-
Assembly
is described in chapter 6.3
on page 21.
5.3.1
Config_assembly_parameter_recognition
This parameter is used to determine whether
Config-
Assembly
is decisive or whether it will be ignored.
If this BOOL is set to 1, the settings made here take
priority over the saved parameters.
If the value is 0, the settings of the
Config-Assembly
are
ignored and the BTL is operated according to the
parameters set in the
Position Sensor Object
or device
configuration object.
5.3.2
Number_of_Magnets
This parameter has the same function as attribute 6 of the
device configuration object (see
5.3.3
Averaging_Filter
This parameter has the same function as attribute 17 of
the device configuration object (see
5.3.4
FMM_Timeout
This parameter is identical in function with attribute 16 of
the device configuration object (see
5.3.5
Direction_Counting_Toggle
This parameter has a similar function to attribute 12 of the
Position Sensor Object
direction reversal (Direction Counting Toggle)
page 10). However, it works on all magnets
simultaneously whilst the corresponding attribute of the
Position Sensor Object
is only valid for one magnet.
5.3.6
Scaling_function_Control
This parameter is identical in function with attribute 14 of
the
Position Sensor Object
(see
function (Scaling Function Control)
also valid for all magnets and all instances simultaneously.
5.3.7
Position_Measuring_Increment
Identical with the parameter 18 bearing the same name in
the
Position Sensor Object
(see
(Position Measuring Increment)
to the individual settings made using the
Position Sensor
Object
, this parameter simultaneously affects all magnets.
5.3.8
Velocity_Resolution
Identical with the parameter bearing the same name in the
Position Sensor Object
(see
on page 12). This parameter also
affects all magnets simultaneously.