www.balluff.com
17
english
8
Interface (continued)
Index Name
Subindex
Data type
Value range
Comment
36
Device Status
UINT8
0 = Device OK
2 = Out of Specification
4 = Failure
Device status
37
Detailed Device
Status
See events
40
Process Data Input
UINT16
Current process data, see
60
Setpoints BDC1
– Set-Point SP1
1
UINT16
R/W
0…4095
Switchpoint 1, see
– Set-Point SP2
2
UINT16
R/W
0…4095
Switchpoint 2, see
61
Switch Point BDC1
R/W
BDC1 configuration
– Logic
1
UINT8
R/W
0 = normal function
1 = inverted
Switching logic
– Mode
2
UINT8
R/W
1 = standard switching
function
2 = 2-point switching
3 = window function
4 = dynamic operation
Switching mode, see
70
SIO Output Type
UINT8
R/W
1 = PNP N.O.
2 = PNP N.C.
3 = NPN N.O.
4 = NPN N.C.
5 = push-pull N.O.
6 = push-pull N.C
Switching power amplifier
71
Debounce
– Delay On
1
UINT16
R/W
0…6500
Switch-on delay × 10 ms
– Delay Off
2
UINT16
R/W
0…6500
Switch-off delay × 10 ms
72
External Trigger
UINT8
R/W
0 = inaktive
1 = teach line active
2 = fill level regulation
If bit 3
Local Parametriza-
tion in the Device Access
Lock parameter
is set, the
External Trigger
input is
active.
73
Display Settings
Record
– Intensity
1
UINT8
R/W
0 = 50%
1 = 100%
– Rotation
2
UINT8
R/W
0 = normal alignment
1 = rotated by 180°
BAE SA-CS-027-YI-BP00,3 GS04
IO-Link Sensor Amplifier
Summary of Contents for IO-Link BAE SA-CS-027-YI-BP00,3 GS04
Page 1: ...BAE SA CS 027 YI BP00 3 GS04 deutsch Betriebsanleitung english User s guide ...
Page 2: ...www balluff com ...
Page 3: ...BAE SA CS 027 YI BP00 3 GS04 Betriebsanleitung deutsch ...
Page 4: ...www balluff com ...
Page 26: ......
Page 27: ...BAE SA CS 027 YI BP00 3 GS04 User s Guide english ...
Page 28: ...www balluff com ...