14
english
7
Operating mode (continued)
Special function
PuMP
Example for fill level regulation with 2 sensors and
amplifiers:
System 1 (amplifier and sensor 1) reports minimum fill level
L1 to system 2 (amplifier and sensor 2) via control line.
System 1 is not used in IO-Link operation.
Fig. 7-6:
MAX
MIN
wh
bk
bk
Ett = PumP
Out = PushPull
L1
L2
Out-
put
1)
Fill level
1)
e.g. for pump control
Special function
Signal linking as follows:
– Output
bk
active if fill level falls below L1 (sensor 1)
(e.g. switching on a pump).
– Output
bk
switches to low as soon as fill level exceeds
L2 (sensor 2) (pump switches off).
After a power failure, the system starts in the last
mode (draining or filling). A maximum of 300,000
cycles is possible.
7.6.3 Setting the switch-on delay
don
►
Set a value for the switch-on delay (value range:
0…6500 × 10 ms).
⇒
Switch-on is delayed by the set value.
7.6.4 Setting the switch-off delay
doF
►
Set a value for the switch-off delay (value range:
0…6500 × 10 ms).
⇒
Switch-off is delayed by the set value.
7.7
Display settings
di SP
7.7.1 Display of software/hardware version
Display Configuration
FW
Firmware version (e.g. FW0214)
HW
Hardware version (e.g. HW0215)
Tab. 7-4: Display of software/hardware version
7.7.2 Adjusting the luminosity
Display Configuration
50
Luminosity at 50%
100
Luminosity at 100%
Tab. 7-5: Adjusting the luminosity
7.7.3 Display text rotation (0/180°)
Display Configuration
0
Text rotated 0°
180
Text rotated 180°
Tab. 7-6: Display text rotation (0/180°)
7.7.4 Dampening rate display in RUN mode
Display Configuration
Off
No display of dampening in digits in RUN
mode
On
Display of dampening in digits in RUN mode
Tab. 7-7: Dampening rate display in RUN mode
7.8
Closing the menu
E nd
►
Press the
button.
⇒
All settings are saved; the display indicates
r un
and the sensor dampening rate in digits.
7.9
Returning to factory settings
►
Briefly press the
and
buttons simultaneously
⇒
After releasing the buttons,
r St
appears on the
display.
BAE SA-CS-027-YI-BP00,3 GS04
IO-Link Sensor Amplifier
Summary of Contents for IO-Link BAE SA-CS-027-YI-BP00,3 GS04
Page 1: ...BAE SA CS 027 YI BP00 3 GS04 deutsch Betriebsanleitung english User s guide ...
Page 2: ...www balluff com ...
Page 3: ...BAE SA CS 027 YI BP00 3 GS04 Betriebsanleitung deutsch ...
Page 4: ...www balluff com ...
Page 26: ......
Page 27: ...BAE SA CS 027 YI BP00 3 GS04 User s Guide english ...
Page 28: ...www balluff com ...