18
english
8
Interface (continued)
8.4
System commands
Value
Command
Description
1
Block
parameterization
ParamUploadStart
Start device – master block parameterization
2
ParamUploadEnd
Stop device – master block parameterization
3
ParamDownloadStart
Start device – master block parameterization
4
ParamDownloadEnd
Stop device – master block parameterization
5
ParamDownloadStore
Stop device – master block parameterization and upload
request
6
ParamBreak
Abort block parameterization
65
Teach
Teach SP1 Single Value
Teach in switchpoint SP1, see section 7.3
66
Teach SP2 Single Value
Teach in switchpoint SP2, see section 7.3
128
Reset
Device Reset
Restart device
130
Reset device settings to factory settings
8.5
Events
Event
Code
Name
Type
Device
Status
Comment
0xFF91
Data Storage Upload Request
Notification
–
Parameters were changed
locally or ParamDownload-
Store system command.
0x4210
Device temperature over-run
Warning
Out of
Specification
0x5111
Primary supply voltage under-run
Warning
Out of
Specification
U
B
< 18 V
0x7700
Wire break / out of specification of a subordinate
device – Check installation
Error
Failure
Check sensor connection /
operate within the
permissible switching
distance.
BAE SA-CS-027-YI-BP00,3 GS04
IO-Link Sensor Amplifier
Summary of Contents for IO-Link BAE SA-CS-027-YI-BP00,3 GS04
Page 1: ...BAE SA CS 027 YI BP00 3 GS04 deutsch Betriebsanleitung english User s guide ...
Page 2: ...www balluff com ...
Page 3: ...BAE SA CS 027 YI BP00 3 GS04 Betriebsanleitung deutsch ...
Page 4: ...www balluff com ...
Page 26: ......
Page 27: ...BAE SA CS 027 YI BP00 3 GS04 User s Guide english ...
Page 28: ...www balluff com ...