6
STARTUP
50
www. matrix-vision.com
BVS SC-_1280Z00-30-0-0
SMART
CAMERA
Fieldbus
www.balluff.com
Device master data
To parameterize the correct
SMARTCAMERA m
odel in an EtherNet/IP network, device
database information in the form of an EDS file is required.
The file is located on the Balluff website(see
The following values describe the data sizes of the input, output and configuration data.
These must be entered in the host system.
Assembly
Instance ID
Data length in bytes
INPUT
100
176
OUTPUT
101
162
CONFIG
102
26
Input Assembly (input data, camera to PLC)
Start
byte
Length Description
0
128
Camera process data. The process data protocol is in the separate
software manual ("BVS Cockpit Manual") under “Appendix → Con-
trol
commands → Communication via fieldbus”.
128
1
Digital inputs:
Bit 0: Pin 4 input data
Bit 1: Pin 2 input data
129
1
IO-Link Device Status:
Bit 0: Port in IO-Link mode
Bit 1: Device is connected
Bit 2: Validierung failed
Bit 3: Short circuit between pins 1 and 3
Bit 4: Pin 4 overload
Bit 5: Pin 2 overload
130
32
IO-Link process data
162
2
IO-Link vendor ID
164
3
IO-Link device ID
167
9
IO-Link 3 events, each 1 byte error code and 2 bytes additional
code
Output Assembly (output data, PLC to camera)
Start
byte
Length Description
0
128
Camera process data. The process data protocol is in the separate
software manual ("BVS Cockpit Manual") under “Appendix → Con-
trol commands → Communication via fieldbus”
128
1
Digital outputs:
Bit 0: Pin 4 output data
Bit 1: Pin 2 output data
129
1
Restart after short circuit:
Bit 0: Pin 4
Bit 1: Pin 2
130
32
IO-Link process data
6.7.7 Process data struc-
ture