4
PRODUCT
DESCRIPTION
23
www. matrix-vision.com
BVS SC-_1280Z00-30-0-0
SMART
CAMERA
Fieldbus
www.balluff.com
IO-Link
LED
Indicator
Function
IO-Link
C/Q
Off
Status of input or output pin is 0
Green on
IO-Link communication active
Flashing green (1
Hz)
No IO-Link communication or wrong IO-Link device
Flashing
green rapidly
IO-Link preoperate during data retention
Yellow on
Status of input or output pin is 1
Flashing red rap-
idly
Validation failed / incorrect configuration of the IO-Link
data length / self-test after switch-on
Rot on
IO-Link short circuit / sensor supply short circuit / firm-
ware update
IO-Link
Pin 2
Off
Status of input or output pin is 0
Yellow on
Status of input or output pin is 1
Red on
Short circuit at output
LAN
LED
Indicator
Function
LAN Link
Off
No LAN connection
Green on
LAN connection established
LAN Act
Off
No data transfer
Yellow flashing
Data transmission
The outside of the camera can be cleaned with a soft cloth. Persistent dirt can be re-
moved with a cloth that is first moistened with a soap solution and wrung out.
→ After wiping off the dirt spots, wipe the camera with a dry cloth.
4.5.4 Cleaning