- 7 -
REMOVAL OF DOORS AND DOOR ADJUSTMENT
During installation, it may become necessary to remove the cabinet doors to
facilitate passage through narrow doorways or hallways. To remove a door, pry off
all hinge covers using a sharp tool or knife (see figure 5). Swing the door to the
open-door position (90 degrees) and carefully lift the door upward, removing the
door from the hinge bodies. If it is necessary to remove the hinge bodies from the
cabinet face, be extremely careful not to lose the light switch pin located inside all
top hinge bodies. To reinstall the door, reverse the above procedure.
All doors have been aligned at the factory, however vibration during transportation
may cause doors to shift and realignment may be necessary.
If the door(s)
require realignment, proceed as follows:
1. Pry off all hinge covers using a sharp tool or knife.
2. For each door, loosen the screws which secure the hinge bodies to the cabinet
face and slide the door into alignment. Hold the door firmly in place and tighten
all screws securely.
If the door gasket(s) do not seal properly to the cabinet face and there are
gaps between the gasket and the face on the hinge edge, proceed as follows:
1. For each door, loosen all screws which are directed into the edge of the door
and push the door towards the cabinet eliminating the gap. Hold the door firmly
in place and tighten all screws securely.
2. Replace all snap-on hinge covers.
FIGURE 5
DOOR ADJUSTMENT AND REMOVAL
Summary of Contents for Refrigerators/Freezers/Warmers