User’s Manual
6
2.2.
Technical characteristics
___________________________________________________________________________________________________________ Table 1
NAME OF THE CHARACTERISTIC
UOM
BaltGaz NEVALUX- 8230
Type of gas
Natural G20 / Liquefied G30
Family; group of gas
2-е; Н / 3-е; B/P
Gas pressure in the duct
kPa
1,3 - 2,0/2,9
Rated heating effect
kW
30,0
Rated heating power
kW
33,0
Rated gas consumption
m3/h
3,50/1,20
Minimal heating effect
kW
10,0
Performance index at rated heating power , not less than
%
92,0
Performance index at rated heating power 30%, not less than
%
90,0
He
ati
n
g
c
ircu
it
Temperature regulation range
°С
30-85
Heat carrier operating pressure
MPa
01-02
Maximum heat carrier pressure
MPa
0,3
Volume of inserted expansion tank
L
6,0
Air pressure in the expansion tank
MPa
0,1
DH
W
circu
it
Water consumption at heating for T=25 °С
l/min
17,0
Temperature regulation range
°С
30-60
Operating water pressure
MPa
0,02 - 0,60
Minimal water pressure, Рmin
MPa
0,015
Maximum water pressure, Рmax
(at water heat expansion pressure must not exceed this value)
MPa
1,0
Minimal water flow for switching the boiler on
l/min
2,5
Minimal water flow for switching the boiler off
l/min
1,5
Specific water consumption, D
dm
3
/min
14,1
Mass consumption of combustion products
g/s
18,0/19,0
Average combustion products temperature
°С
120
Type of combustion products outlet
Forced
Heat carrier
Water,
Propylenglycolum
Heat carrier circulation type
Air-tight forced circulation
Ignition type
Automatic ignition, electronic ignition
Maintenance of set temperature
Automatically kept with accuracy ±1 °С
Temperature indication
LCD display
Rated power tension
V
220 ±10%
Rated electric current frequency
Hz
50
Maximum electric power consumption
kW
0,150
Safety fuse
А
2
Electrosecurity class
I
Protection rate
IP X4D
Overall dimensions: height widths x depth
mm
720x410x326
Net/ Gross weight
kg
35,0 / 37,5
Co
n
n
ec
ti
o
n
d
ime
n
sio
n
s
Gas inlet
inch
G3/4
CHinlet and output
inch
G3/4
DHW circuit inlet and output
inch
G1/2
Inlet air orifice / Output orifice for combustion products (for
coaxial pipes)
mm
Ø 100 / Ø60
(Inlet air orifice / Output orifice for combustion products (for
separate pipes)
mm
Ø 80 / Ø80
Summary of Contents for NEVALUX-8230
Page 35: ...Assembly is performed in reverse order Scheme 23 Heat exchanger dismantling...
Page 41: ...48...
Page 47: ...Ignition and ionization plugs in the assembly pos 67...
Page 54: ......
Page 55: ......