6 / 18
0006081359_200906
BPM 35
SM
BPM 140
SM
BPM 200
SM
BPM 300
SM
POTENZA TERMICA /
THERMIC CAPACITY
MIN
kW
21,6
28
40
60
MAX
kW
42,5
140
200
300
TENSIONE / VOLTAGE
1N - 50/60Hz - 230V
POTENZA ELETTROVENTILATORE / FAN POWER
W
80
200
360
TRASFORMATORE D’ACCENSIONE /
IGNITION TRANSFORMER
15kV - 25mA
Gas naturale / Natural Gas (G20)
PORTATA / FLOW RATE
MIN
m³/h
2,28
2,96
4,23
6,03
MAX
m³/h
4,49
14,81
21,16
30,17
PRESSIONE / PRESSURE
mbar
20
ATTACCO ENTRATA GAS
3/4"
1"
CARATTERISTICHE TECNICHE
b
b
b
APPLICAZIONE DEL BRUCIATORE ALLA CAME
-
RA DI COMBUSTIONE
a
- Togliere il cofano "a"
- fissare il bruciatore con i n°4 dadi "b"
- Remove burner cover "a"
- fix the burner by mean of n°4 nuts "b"
TECHNICAL SPECIFICATIONS
INSERT BURNER INTO COMBUSTION CHAMBER
ITALIANO
ENGLISH