9 / 28
0006081325_201210
ENGLISH
PIPES FOR LIGHT OIL BURNERS MODEL TBL 85P/ P DACA - 105P/ P DACA
GRAVITY SUPPLY SYSTEM
1 Tank
2 Feeding pipe
3 Wire-net filter
4 Pump
5 Degasifier
6 Suction pipe
7 Return pipe
8 Automatic fuel interception
device at burner shut off
9 Non-return valve
DROP-TYPE SYSTEM WITH SUPPLY FROM THE TANK TOP
1 Tank
3 Wire-net filter
4 Pump
6 Suction pipe
7 Return pipe
8 Automatic fuel interception
device at burner shut off
9 One-way valve
10 Bottom valve
SUCTION - TYPE FEEDING SYSTEM
N.B.
For any missing devices in the piping, follow existing regulations.
H = Difference in level between level in the tank and the pump axis.
L = Maximum length of suction pipe including the vertical lift.
For each bend or valve deduct 0,25 m.
P = 3,5 m. (max.)
H
Total meters
meters
meters
Ø i. 14 mm.
1
30
1,5
35
2
35
2,5
40
3
40
H
Total meters
meters
meters
Ø i. 14 mm.
1
30
1,5
35
2
35
2,5
40
3
40
PUMP AXIS
PUMP AXIS
1 Tank
3 Wire-net filter
4 Pump
6 Suction pipe
7 Return pipe
10 Bottom valve
PUMP AXIS
H
meters
Total meters
meters
Ø i. 14
mm.
Ø i. 16
mm.
0,5
26
45
1
22
38
1,5
19
31
2
14
25
2,5
11
19
Summary of Contents for TBL 105P
Page 2: ......
Page 26: ...26 28 0006081325_201210 ENGLISH ELECTRIC DIAGRAM ...
Page 27: ...27 28 0006081325_201210 ENGLISH ...
Page 52: ...26 28 0006081325_201210 ESPAÑOL ESQUEMA ELECTRICO ...
Page 53: ...27 28 0006081325_201210 ESPAÑOL ...
Page 78: ...26 28 0006081325_201210 FRANÇAIS SCHEMA ELECTRIQUE ...
Page 79: ...27 28 0006081325_201210 FRANÇAIS ...
Page 104: ...26 28 0006081325_201210 DEUTSCH SCHALTPLAN ...
Page 105: ...27 28 0006081325_201210 DEUTSCH ...
Page 107: ......