Chapter Five – Safety Index
Input Voltage
220-240V
Power
250W
Frequency
50Hz
Continuous working
period
≤20 Min
Spacing interval
≥5 Min
Chapter Six – Fault Analysis & Removal
Fault phenomenon
Fault Analysis
Fault Removal
Push the "Switch" and No
feedback
1. Check the power cord and confirm
it is connected.
2. The power protection stops working
because the food material is too hard.
1.
Connect the power cord.
2.
Replace or cut ingredients into small
pieces before using.
Smell from the motor running
at the first few time use.
It's common for a new motor.
Send to our maintenance point for
repair if it still have smell after using
many times.
Stop working at midway.
1. Too much fruit in the feeding tube
which caused overload or block up.
2. The power plug is loose.
1. Stop adding fruit and push it inwards
with the pusher slightly.
2. Plug the power supply again.
Too much slag in the juice.
Filter is damaged.
Replace with a new filter.