Starting & Stopping

Plug the compressor into an outlet socket of nominal voltage and fitted with a 13 amp fuse.

Switch the compressor on using the on/off control on top of the pressure switch.  

see fig 3

The compressor will start running and automatically switch off at the preset pressure.

As air is used, the pressure drops and the motor will restart at the preset pressure.  Approx 2 Bar differential.

Note! 

Never tamper with the pressure switch settings; these are factory set.

Adjusting Outlet Pressure

Use the filter regulator to adjust the outlet pressure. The 40mm pressure indicates the selected pressure. To increase line 

pressure, rotate the black knob on top of the filter regulator in a clockwise manner; to decrease turn anti clockwise.  It is 

possible to lock the setting by pushing the knob down until it “clicks” home – see fig 4

Routine Maintenance

Draining the Air Receiver

Drain condensate from air receiver at a pressure of no more than 2 Bar.  

Slowly open the drain tap provided to allow water to flow out – see figs 7 & 8

Close drain tap when all water has drained off.  

Do not overtighten; this will damage the tap seal.

Automatic drains where fitted do not require draining, however the drain bottle will require emptying.

Draining the Filter/Regulator Unit

Slowly open the drain screw provided to allow water to flow out.

Close drain screw when all water has drained off - see fig 5

Note !

Waste condensate must be handled in accordance with national environmental rules.

Check Pressure Relief Valve

Ensure the air receiver is not pressurised. 

 

Unscrew the knurled end of the pressure relief valve until an audible “click” is heard.  

Retighten without using excessive force – see fig 6

Technical

The compressor has a maximum 50% duty cycle.  The motor must never be allowed to run continuously; otherwise it will 

overheat and may become damaged.

Do not ignore air leaks.  

All air connections must be leak free to prevent the compressor from over heating.

The compressor is fitted with a thermal overload.  In the event of excessive temperature, the motor will switch off.  After about 

50 minutes when the motor has cooled, it will automatically reset.  

Note!

You must find the cause of the overload and rectify this before continuing to use the compressor.
Check for -

 

• 

Drain tap not closed properly

 

• 

Air leaks on the pneumatic fittings 

 

• 

Compressor not the correct size for the work load

Preventative Maintenance

Operation

Daily

Weekly 

Monthly

Annually

Drain Air Receiver < 15 Litres

Drain Air Receiver > 15 Litres

Drain Filter Regulator

Check Oil Level

Change Oil

Replace Air Intake Filter

Replace Filter Regulator Element 

Check Pressure Relief Valve Activation

Above are to be considered minimum frequency

Topping up oil

Ensure the oil level in the sight glass is at or above 

the halfway point, top up with Bambi BPB1110S oil 

if required until oil fills sight glass - see fig 2

Summary of Contents for BB15V

Page 1: ...get Range Operators Handbook BAMBI AIR COMPRESSORS LTD 152 Thimble Mill Lane Heartlands Birmingham B7 5HT United Kingdom Tel 0121 322 2299 Fax 0121 322 2297 Email sales bambi air co uk www bambi air co uk ...

Page 2: ... oil does not contain hazardous components and is not required to be labelled dangerous according to the Classification Packaging and Labelling of dangerous substances regulation CPL Regulation 1984 Siting The Compressor What you must do Provide adequate protection from the weather Site the compressor level in both plains Larger models are heavy ensure the surface has sufficient load bearing capac...

Page 3: ...Close drain screw when all water has drained off see fig 5 Note Waste condensate must be handled in accordance with national environmental rules Check Pressure Relief Valve Ensure the air receiver is not pressurised Unscrew the knurled end of the pressure relief valve until an audible click is heard Retighten without using excessive force see fig 6 Technical The compressor has a maximum 50 duty cy...

Page 4: ...eceiver 15 litre BPB0469 2 Wheel BPB1144 3 Wheel cap BPB1108 4 Inspection plug BPB0243 5 Inspection plug seal BPB0502 6 Delivery hose 300mm BPB1087 7 Non return valve BPB1086 8 Relief valve BPB1084 9 1 4 tee BPB1109 10 Pressure switch BPB1074 11 1 4 x 1 4 connector BPB1078 12 On off valve BPB1079 13 Filter regulator unit BPB1080 14 40mm pressure gauge BPB1077 15 50mm pressure gauge BPB1081 16 1 4 ...

Page 5: ...eceiver 24 litre verticle BPB0472 2 Non return valve BPB1086 3 Delivery hose 200mm BPB1102 4 Relief valve BPB1084 5 Pressure switch BPB1074 6 1 4 x 1 4 connector BPB1078 7 1 4 MF elbow BPB1139 8 Filter regulator unit BPB1080 9 40mm pressure gauge BPB1077 10 On off valve BPB1079 11 50mm pressure gauge BPB1081 12 1 4 tee BPB1095 13 On Off Valve BPB0895 14 6mm Drain tube BPB0203 15 Inspection plug BP...

Page 6: ...2 4 Delivery hose 200mm BPB1102 5 1 4 tee BPB1285 6 Delivery hose 300mm BPB1087 7 Non return valve BPB1086 8 Relief valve BPB1084 9 1 4 tee BPB1109 10 On Off Valve BPB0895 11 6mm Drain tube BPB0203 12 Siphon tube BPB0034 13 Pressure switch BPB1074 14 1 4 x1 4 connector BPB1078 15 On off valve BPB1079 16 Filter regulator unit BPB1080 17 40mm pressure gauge BPB1077 18 50mm pressure gauge BPB1081 19 ...

Page 7: ...get Pump Specification Motor Kw Hp 0 37 0 5 Voltage 220 240 Frequency Hz 50 Amps 3 Watts 660 Displacement l min 50 Fig 5 Fig 6 Fig 1 Fig 4 Fig 7 Top mounted drain Fig 3 On Off Fig 8 Bottom mounted drain Fig 2 Inlet filter BPB1003 ...

Page 8: ...sous Bambi Air Compressors declara que este producto cumple con la DirectivaEuropea listada abajo Bambi Air Compressors verklaart dat dit product voldoet aan de onderstaande Europese Richtlijnen Bambi Air Compressors erklart hiermit dass dieses Produkt mit den Bestimmungen der Nachstehenden EU Richtlinien ubereinstimmt Machinery Directive 2006 42 EC Electromagnetic Compatibility 2014 30 EU Simple ...