4
Preventative Maintenance
Operation
Daily
Weekly
Monthly
Annually
Drain air receiver < 15 Litres
•
Drain air receiver > 15 Litres
•
Drain filter regulator
•
Check oil level
•
Change oil
•
Replace air intake filter
•
Replace filter regulator element
•
Check pressure relief activation
•
Above are to be considered minimum frequency
Technical Specification
Type 35 Pump Specification
Voltage
220/240
Motor Kw / Hp
0.37 / 0.5
Frequency Hz
50
Amps
2.4
Watts
340
Displacement l/min
50
FAD@ 6 Bar
33
Type 75 Pump Specification
Voltage
220/240
Motor Kw / Hp
0.5 / 0.5
Frequency Hz
50
Amps
3.6
Watts
500
Displacement l/min
78
FAD@ 6 Bar
54