PT Range Operators Handbook
PT models

Covering Models:-

BAMBI AIR LTD

152 Thimble Mill Lane

Heartlands

Birmingham

B7 5HT

Tel:  0121 322 2299

Fax: 0121 322 2297

Email: sales@bambi-air.co.uk

www.bambi-air.co.uk

PT5  /  PT15  /  PT24  /  PT50

Summary of Contents for PT Series

Page 1: ...perators Handbook PT models Covering Models BAMBI AIR LTD 152 Thimble Mill Lane Heartlands Birmingham B7 5HT Tel 0121 322 2299 Fax 0121 322 2297 Email sales bambi air co uk www bambi air co uk PT5 PT15 PT24 PT50 ...

Page 2: ... on the company Provided the operating instructions have been followed and the compressor has been properly maintained Bambi PT compressors are guaranteed against faulty workmanship for a period of 1 year The air receiver is guaranteed for 5 years The guarantee does not cover damage by misuse incorrect parts or service Contact Bambi Air Ltd or your retailer for further information Technical Specif...

Page 3: ...ite the compressor level in both planes Allow access for maintenance all around the compressor Site in a dry area avoiding damp or humid conditions The site must be dust free well ventilated and have a cool ambient temperature 0 to 40 C should be regarded as the minimum and maximum allowable ambient What you must not do Enclose the compressor or allow hot air generated by the motor to re circulate...

Page 4: ... differential Note Each time the compressor switches off you will hear a short hiss of air You are hearing the unloader valve discharging the residual delivery pipe pressure This is normal Adjusting Outlet Pressure Use the pressure regulator to adjust the outlet pressure To increase line pressure rotate the knob in a clockwise direction to decrease turn anti clockwise It is possible to lock the se...

Page 5: ...mpressor has a maximum 65 duty cycle to prolong pump life Note The motor must never be allowed to run continuously otherwise it will overheat and may become damaged The duty cycle is calculated over 10 minutes meaning that if the motor runs continuously for 6 5 minutes it must then rest for 3 5 minutes Do not ignore air leaks All air connections must be leak free to prevent the compressor from ove...

Page 6: ...ssure switch BPB1074 10 Adapter BPB1078 11 On off tap BPB1079 12 Regulator BPB1080 13 40mm line pressure gauge BPB1077 14 Elbow M F BPB1139 15 Foot BPB1295 16 50mm tank pressure gauge BPB1081 17 Delivery pipe BPB1258 18 3 8 x M14 x 1 8 Connector BPB1300 19 Elbow for air pipe BPB0044 20 Air pipe BPB0203 21 Inserts BPB0078 22 Non Return valve BPB0656 23 1 8BSP Plug BPB0823 24 1 4 x 3 8 Adapter BPB09...

Page 7: ... Non return valve BPB0656 8 Pressure relief valve BPB1084 9 Pressure switch BPB1074 10 Adapter BPB1078 11 On off tap BPB1079 12 Regulator BPB1080 13 40mm line pressure gauge BPB1077 14 Elbow M F BPB1139 15 Elbow BPB1257 16 Connector BPB0810 17 50mm tank pressure gauge BPB1081 18 Delivery pipe BPB1258 19 1 8BSPM x 6mm Push fit elbow BPB0044 20 1 8BSP Plug BPB0823 21 1 4 x 3 8 Adapter BPB0918 22 3 8...

Page 8: ...079 12 Regulator BPB1080 13 40mm line pressure gauge BPB1077 14 Siphon tube BPB0028 15 Connector BPB0152 16 50mm tank pressure gauge BPB1081 17 Delivery pipe BPB1258 18 Connector BPB1242 19 Tee piece MMM BPB1239 20 1 8BSPM x 6mm Push fit elbow BPB0044 21 3 8 x M14 x 1 8 Adapter BPB1300 22 Air pipe BPB0203 23 Elbow BPB1257 24 Capacitor box BPB1236 25 Capacitor BPB1260 26 1 8BSP Plug BPB0823 27 1 4 ...

Page 9: ...ription Part no 1 Cylinder head seal BPB1250 2 Valve plate assembly BPB1251 3 Cylinder BPB1253 4 Piston ring BPB1254 5 Airway tube inc O ring seal BPB1252 6 Motor fan LH BPB1255 7 Motor fan RH BPB1264 8 Fan cover BPB1256 9 Air intake filter BPB1259 ...

Page 10: ...Notes 8 ...

Page 11: ...SERVICE RECORD Date installed____________________________ Date Maintenance work Signature Company BPPT 1 Service Kit covers all models PT50 requires two kits SERVICE KITS 9 ...

Page 12: ...nderstaande Europese Richtlijnen Bambi Air Ltd erklart hiermit dass dieses Produkt mit den Bestimmungen der Nachstehenden EU Richtlinien ubereinstimmt Machinery Safety Standard 89 392 EC Low Voltage Directive 2006 95 EC Machinery Directive 2006 42 EC Electromagnetic Compatibility 2004 108 EC Simple Pressure Vessels 2009 105 EC EN60034 EN60204 1 2007 EN ISO12100 1 2 2005 EN ISO13857 2010 CE Marking...