AIR DRYER PERFORMANCE
Where fitted, the air dryer unit was tested using a Michell
Instruments C2TX Hygrometer
The test procedure was carried out in accordance with ISO8573-1 Class
9.2.9:2010 Class 9.2.9
Molecular Sieve Type BS4A 2.5/5.00mm
Test Result: -40 Degree Dew Point
Duty Cycle Time: Full Flow @50%
Performance: [100% pass]
NOTE: To ensure the optimum performance of your Bambi dryer please
note that the desiccant and filter need to be changed every two years
or if the Dew Point level is no longer achieved due to degradation of the
desiccant in extreme working conditions.
36
Summary of Contents for VT150
Page 39: ...37 NOTES ...