5
You must find the cause of the overload and rectify this before continuing to use the
compressor.
Check for -
Drain tap not closed properly
Air leaks on the pneumatic fittings
Compressor not the correct size for the work load
If problems persist contact your dealer.
•
•
•
Technical
We recommend the compressor has a maximum 50% duty cycle to prolong pump
life. The motor must never be allowed to run continuously otherwise it will overheat
and may become damaged
Do not ignore air leaks. All air connections must be leak free to prevent the
compressor from over heating.
The compressor is fitted with a thermal overload. In the event of excessive
temperature the motor will switch off. To re-set the overload follow the procedure
below :-
Models VT75/75D, VT150/150D,
VT200/200D
Motor Sizes 0.75Hp, 1.5Hp, 2.0Hp
Switch off at the pressure switch.
Allow 50 minutes for the motor to cool
down.
Switch on at the pressure switch.
Models VT300/300D, VT400/
400D
Motor Size 2x1.5Hp – 2x2.0Hp
The re-set is integral with the pressure
switch.
The pressure switch will automatically
turn off (O) in the event of motor
overload.
Turn the pressure switch to the on
position (I).