background image

Pillar

External
opening. 
External motor.

External
opening. 
Internal motor.

WITH THIS KIND OF
INSTALLATION,
ABOUT 60 WALKING
SPACE CM ARE LOST

11

Special installation

Pillar

Swing hinge

Swing hinge

Swing

Swing

Front stirrup

Front
stirrup

Rear
stirrup

Rear
stirrup

C

B

B

A

A

740 mm

Summary of Contents for TIGER 230 V

Page 1: ...reversible motoreducer for swings gates up to 3 5 meters Residential use 230 V Intensive use 24 V 1 READ THIS MANUAL CAREFULLY BEFORE PROCEEDING WITH THE INSTALLATION KEEP THIS MANUAL FOR FUTURE REFERENCE Installer manual ...

Page 2: ... emergency release system to be used in case of power supply failure placed above each motor in order to allow the moving of the swing The 24 V operator can be provided with an emergency battery for the automatic move of the swing also during a black out Technical features Main supply Power supply Power Current Working temperature Working stroke Time for a 95 opening Max thrust Grade of protection...

Page 3: ... respect Pre installation check Verify that the swing of the gate can rotate properly without hangings it s straight and moving without oscillations the hinges must keep the swing in axis have mechanical swing stopper installed these problems if present must be corrected before installing the motor Standard specifications These standards define the mechanical requisites needed for motorised reside...

Page 4: ...k must not be present it s extened up to 2 5 mt of height BAME s r l is liable only for the individual articles produced and sold by BAME the gate with the motor it s considered a machine and must respect the machinery directives the installer must verify the safety of the gate with the motor and is liable for any damage due to a poor installation ATTENTION BAME is not liable for any damage depend...

Page 5: ... the key in the opposite way Important at the end of the release operation always close the plastic cap firmly ATTENTION THIS SHEET MUST BE CONSIGNED TO THE CLIENT ATTENTION THE CUSTOMER MUST KEEP THIS SHEET TOGETHER WITH THE UNLOCKING KEY IN A SAFE PLACE THE PLACE WHERE THE KEY IS STORED MUST BE ACCESSIBLE ALSO IN CASE OF POWER FAILURE ATTENTION INFORM ALSO OTHER USERS OF THE AUTOMATION ABOUT THE...

Page 6: ...3 23 EEC 89 336 EEC 98 37 EEC and subsequent modifications Furthermore declare that the following standard specifications have been applied EN12453 EN12445 Safety for motorised doors and gates industrial commercial and residential Requisites and classification Test methods EN12604 EN12605 Mechanical aspects for doors and gates industrial commercial and residential Requisites and classification Tes...

Page 7: ...all the technical regulations applicable to the product within the scope of Council Directives MACHINERY DIRECTIVE 98 37 CEE AND SUBSEQUENT MODIFICATIONS DIRECTIVE EMC 89 336 CEE DIRECTIVE BT 73 23 CEE AND 93 68 CEE IS FORBIDDEN TO PUT INTO SERVICE THE DEVICE OF THIS DECLARATION BEFORE THE PRODUCT OF THE DECLARATION A HAS BEEN DECLARED IN COMPLIANCE WITH THE SPECIFICATIONS STANDARD San Giacomo Seg...

Page 8: ...s 2 sensitive edges 3 photocells 4 swing stoppers 5 torque limiter 6 surface modelling 7 footboards 8 radar 9 acustic signal 10 visual signal 11 markings 12 isolation 13 protection net 14 15 Electrical risks CE markings are present in compliance with the directive BT 73 23 CEE All electrical connections are made in compliance with standard specifications also according to the manufacturer manual T...

Page 9: ...e motors to the stirrups with the screws supplied check the electrical wirings and verify that the motors are working smoothly first by hand and then with the control board to program the motors check the manual supplied with the electronic control board Fig 6 Stirrups fixing measures with closed gate Max opening Quote A Quote B Quote C 95 145 mm 165 mm 1030 mm 120 110 mm 190 mm 1030 mm NB For a c...

Page 10: ...o maintain a high reliability also after years of use the system must be checked each six month by authorized personnel Checks to be done during the inspection Lubricate the gate hinges Check the emergency release system Keep the place of the gate and photocells free from trees insects and stuffs which can cause a bad working of the motor Check the motor stirrups and the fixing pins Check the clut...

Page 11: ...or External opening Internal motor WITH THIS KIND OF INSTALLATION ABOUT 60 WALKING SPACE CM ARE LOST 11 Special installation Pillar Swing hinge Swing hinge Swing Swing Front stirrup Front stirrup Rear stirrup Rear stirrup C B B A A 740 mm ...

Page 12: ...nd accessories are guaranteed for a period of 24 months after production whose date is printed on each item The company will replace or repair its devices provided that they are returned to our factory with the warranty label in good conditions In case of replacement of the returned items these will remain property of the company The warranty does not i nclude damages due to any incorrect use such...

Reviews: