TECHNICAL DATA (continued)
Sludge Level Probe (NivOil SP)
Exclusively for connection to the sensor supply unit (NivOil CU)!
Material sensor
PVC
Cable
Standard with 10m oil / petrol resistant cable 2x1mm²
Other cable lengths on request
Maximum permissible cable length: 300m
[C ≤ 200 nF/km and L ≤ 1 mH/km]
Cable colour
blue
Dimensions
ca. 145x90x25mm
Protection
IP68
Measuring principle
Ultrasound
Ambient temperature
-20°C...+60°C
EU Type Examination Certificate BVS 09 ATEX E 021 X
Ex-maximum values
Maximum input voltage Ui
17.9V DC
Maximum input current Ii
157mA
Maximum input power Pi
695mW
Maximum internal capacity Ci
0.14nF/m
(no mixed parameters)
Maximum internal inductance Li
70μH/m
(no mixed parameters)
Ex marking
㐀 II 1G Ex ia IIB T4 Ga
(intrinsically safe electrical equipment)
Interconnection
Sensor supply unit (NivOil CU) with sludge level probe (NivOil SP)
Note!
Use only in stagnant or slow-flowing media.
Strong mechanical impacts on the probe housing must be avoided during installation, maintenance work and operation.
Clean only with a damp cloth, avoid electrostatic discharges.
Special conditions for safe use
The connection line of the sludge level probe (NivOil SP) must be routed through the separation between areas with category 1G requirements
and less hazardous areas in such a way that protection class IP67 in accordance with EN 60529 is ensured.
The sludge level probe (NivOil SP) and connection cable may only be used in areas where electrostatic discharges cannot occur.
The technical information for using the sludge level probe (NivOil SP)
- in connection with aggressive/corrosive media
- with regard to protection against impact
- with regard to the flow velocity of the media
- Cleaning
are to be observed.
LEV
21-03-2023
M-531.01-EN-AI
OIL/LIGHT LIQUID
SEPARATOR MONITORING
NivOil - (translation)
22, Rue de la Voie des Bans · Z.I. de la gare · 95100 ARGENTEUIL
Tel
Fax
+33 (0)1 30 25 83 20
+33 (0)1 34 10 16 05
Web
www.bamo.eu
export@bamo.fr
INTERNATIONAL
531-01
/20